Slurry Analytical System (Standalone Analysis Software) en Nagano, Japón
Nuevo
Doubleclick to zoom in
Contacte al vendedor
para más fotos y información.
Especificaciones
- Condición
- nuevo
- System requirements (computer)
- OS: Windows 10, Windows 11 RAM: 8 GB or more Storage: 1 GB or more of available space Display: resolution 1920 × 1080 or more is recommended Interface: USB 2.0 / 3.0, LAN .NET Framework: 4.7.2 or more
- Instrument to be controlled
- LCR Meter IM3536
- License authentication
- Authentication method: USB license key (included accessory)
- Language
- English, Japanese
- Measurement
- Sweep frequency setting: 4 Hz to 8 MHz (when connected to IM3536) Measurement signal level: 10 mV to 1 V (constant voltage [CV] mode) Nyquist plot display
- Analysis
- Analysis method: Equivalent circuit analysis of impedance data Calculation parameters: DCR, Rratio of each relaxation, uniformity of each relaxation
- Dimensions
- Approx. 98W × 38H × 24D mm (3.9W × 1.5H × 0.9D in.) (excluding protruding parts)
- Weight
- Approx. 210 g (7.4 oz.)
- Material
- Container: polypropylene (PP), electrode: brass (base metal)
- Capacity
- Approx. 1 mL
- Electrode pin
- Diameter (Area where liquid to be measured comes in contact): 3 mm ±0.1 mm Electrode interval: 6 mm ±0.3 mm Electrode surface treatment: nickel plating (SA9001), gold plating (SA9001-01)
- Operating temperature and humidity range
- 23°C ±5°C (73°F ±9°F), 80% RH or less (non-condensing)
- Storage temperature and humidity range
- −10°C to 50°C (14°F to 122°F), 80% RH or less (non-condensing)
- Operating environment
- Indoors, altitude up to 2000 m (6562 ft.)
- Measurable frequency
- DC to 10 MHz
- Connectable sample
- Electrode Cell SA9001
- Residual impedance
- Residual resistance during short circuit 200 mΩ or less (reference for 100 Hz) Inter-electrode stray capacitance 0.2 pF or less (reference for 1 MHz)
- Included accessory
- Shorting plate for compensation
- Categoría
- Advanced technologies
- ID de Anuncio
- 107922833
Descripción
Analytical Software SA2634 empowers battery researchers and quality assurance teams to objectively quantify the conductivity of lithium-ion battery (LiB) slurries. By providing clear metrics like DCR, Rratio, and Uniformity, it helps optimize R&D processes and production efficiency, enabling faster identification of high-performing slurries without relying on subjective assessments. This leads to superior electrode sheets and cells, reducing development time and improving overall battery yield.
Dedicated measuring instruments & software designed for impedance measurement of LIB electrode slurry
Automatic analysis function without the need for equivalent circuit creation or initial value setting
Quantitative evaluation of electronic conductivity using DCR, Rratio, and Uniformity
Assess cathode/anode slurries, conductive pastes, or CNT dispersions with as little as 1 mL — no pretreatment required.