Agilent 7890A GC System with Agilent G7000B QQQ GC/MS Triple Quad en Markham, Ontario, Canadá
Renovado
Doubleclick to zoom in
Contacte al vendedor
para más fotos y información.
Especificaciones
- Condición
- renovado
- Número de stock
- GC/MS-00-0069
- Mode
- EI (High Sensitivity Extraction Source)
- Ion source material
- Noncoated, proprietary inert source
- Ion source temperature
- 106 to 350 °C
- Filaments
- Dual filaments for EI
- Electron energy
- 10 to 300 eV
- Mass range (m/z)
- 10 to 1,050
- Resolution (width at half height)
- Selectable, 0.7 to 2.5 Daltons using default tune Settable, 0.4 to 4.0 Daltons using custom tune
- Dynamic range (electronic)
- >106
- Scan rate (electronic)
- Up to 6,250 u/s
- Minimum mrm dwell
- 1 msec
- Mass filters (2)
- Proprietary monolithic hyperbolic gold-coated quadrupole
- Mass axis stability
- < ± 0.10 u over 24 hours (10-40 °C)
- Quadrupole temperature
- 106 to 200 °C
- Collision cell
- Linear hexapole
- Collision cell gas
- Nitrogen with helium quench gas for reduction of metastable helium
- Collision energy
- Selectable up to 60 eV
- Detector
- Triple-Axis HED-EM with extended-life EM and dynamically ramped-iris
- Tuning
- Autotune or manual
- Total gas flow
- Up to 8 mL/min GC carrier plus another 5 mL/min of methane for CI operation, plus an additional 1–2 mL/min of N2and He for the collision cell gases
- Pumping system
- Dual stage turbomolecular pump
- Software
- Agilent MassHunter acquisition, data handling (quant/qual) and reporting
- Simultaneous ms and gc
- Can collect 2 GC detector signals while acquiring MS data
- Categoría
- Cromatografía en Canadá
- Subcategoría
- Mass spectrometry
- Subcategoría 2
- Gc-ms or gc-ms/ms
- Subcategoría 3
- Triple quadrupole ms
- ID de Anuncio
- 26187997
Descripción
The Agilent 7000B Triple Quadrupole GC/MS/MS is the latest addition to Agilent\’s MS portfolio. Scientists performing \”target compound analysis\” in SIM mode on complex samples will find many ways to use its increased selectivity and sensitivity. MS/MS reduces sample prep, shortens analysis cycles, eliminates false results, and simplifies data review for improved productivity. Based upon time-tested MSD components, the 7000B sets a higher standard for robust GC/MS/MS operation. The entire system and analysis process are supported by MassHunter software, which is designed to make MS analyses easier—from tuning to final report.
System includes:
7000B Triple Quadrupole Mass Spectrometer
7890A or 7890B GC
7693 Liquid Autosampler with 150 position tray or other
Rough pump
PC with data
Servicios Ofrecidos por el Vendedor
Este vendedor ofrece servicios de reparación y mantenimiento
Este vendedor ofrece piezas de repuesto