Agilent 1290 Infinity UHPLC System with G4212A Diode Array Detector en Markham, Ontario, Canadá
Renovado
Doubleclick to zoom in
Contacte al vendedor
para más fotos y información.
Especificaciones
- Condición
- renovado
- Número de stock
- A129-0IUH-PLCS-G4212A
- Hydraulic system
- Two dual pistons in series pumps with proprietary servo-controlled variable stroke design, power transmission by ball screws, smooth motion control of pistons for active damping.
- Settable flow range
- Setpoints 0.001—5 ml/min, in 0.001 ml/min increments. Executed in 300 pl/step increments
- Flow precision
- ≤0.07 % RSD or 0.005 min SD, whatever is greater (0.2—5.0 ml/min). Based on retention time at constant room temperature.
- Flow accuracy
- ±1 % or 10 μl/min, whatever is greater. Pumping degassed H2O at 10 MPa (100 bar)
- Pressure operating range
- Operating range up to 120 MPa (1200bar), up to 2ml/min, 80MPa (800 bar) at 5 ml/min.
- Pressure pulsation
- <1 % amplitude or < 0.5 MPa (5 bar), whatever is greater. At 1 ml/min water
- Compressibility compensation
- Automatic, pre-defined, based on mobile phase selection.
- Gradient formation
- High pressure binary mixing.
- Delay volume
- Jet Weaver V35: <45 μl Jet Weaver V100: <75 μl
- Composition range
- Settable range: 0 – 100 %
- Composition precision
- <0.15 % RSD, or 0.01 min SD, whatever is greater. 0.2 —5.0 ml/min; based on retention time at constant room temperature
- Composition accuracy
- ±0.35 % absolute (5 – 95 %, 0.2 – 5.0 ml/min)
- Solvent selection valve
- Default
- Integrated degassing unit
- Number of channels: 2Internal volume per channel: 1.5 mL
- Control
- Agilent ChemStation for LC (B.04.02 or above) EZChrom Elite (3.3.2 SP1 or above) OpenLAB (3.3.2 SP3) Masshunter (B.02.01 SP1 or above)
- Local control
- Agilent Instant Pilot (G4208A) (B.02.08 or above)
- Communications
- Controller-area network (CAN), RS232C, APG remote: ready, start, stop and shutdown signals, LAN
- Safety and maintenance
- Extensive diagnostics, error detection and display (through Agilent Lab Advisor), leak detection, safe leak handling, leak output signal for shutdown of the pumping system. Low voltage in major maintenance areas.
- Glp features
- Early maintenance feedback (EMF) for continuos tracking of instrument usage in terms of purge valve switches and volume of pumped mobile phase with pre-defined and user settable limits and feedback messages. Electronic records of maintenance and errors.
- Housing
- All materials recyclable.
- Precision
- Typically <0.25 % RSD from 5 – 20 µL Typically <0.5 % RSD from 2 – 5 µL volume Typically <0.7 % RSD from 1 – 2 µL volume
- Pressure range
- Up to 1200 bar
- Injection range
- 0.1 – 20 µL in 0.1 µL increments
- Sample viscosity range
- 0.2 – 5 cp
- Sample capacity
- 2 x well plates (MTP) + 10 x 2 mL vials
- Carry over
- Typically <0.004 %
- Injection cycle time
- Typically <21 s using following standard conditions:Default draw speed: 100 µL/min Default eject speed: 100 µL/min Injection volume: 5 µL
- Temperature range
- Settable from 4°C to 40°C in 1°C increments
- Temperature accuracy at ambient temperatures < 25°c and humidity < 50%
- 3°C to 8°C at a setpoint of 4 °C
- Temperature accuracy at ambient temperatures <30°c and humidity <60%
- 3°C to 9°C at a setpoint of 4°C
- Categoría
- Cromatografía en Canadá
- Subcategoría
- Hp / agilent hplc
- Subcategoría 2
- Hp/ agilent systems
- Subcategoría 3
- Hplc, uplc & ic products
- ID de Anuncio
- 48066241
Descripción
(1) Agilent 1290 G4220A Binary Pump
(1) Agilent 1290 G4226A Infinity Sampler
(1) Agilent 1290 G1330B Autosampler Thermostat
(1) Agilent 1290 G1316C Thermostatted Column Compartment (TCC)
(1) Agilent 1290 G4212A Infinity Diode Array Detector (DAD)
Agilent 1290 G4220A Binary Pump
Agilent 1290 G4226A Infinity Sampler
Agilent 1290 G1330B Thermostat
Agilent 1290 G1316C Thermostatted Column Compartment
Temperature precision specification of ± 0.05 degrees for repeatable retention times and peak areas.
Maximum application flexibility through Peltier cooling and heating for two independent temperature zones from 10°C below ambient temperature up to 100°C.
Low dispersion – optimized for low internal volume contribution.
Spacious column racks provide room for three 30 cm columns or several shorter columns.
Ultra high pressure valves for many applications such as alternating column regeneration, sample preparation and dual or multi-column selection.