MEMORY HiCORDER MR6000 en Nagano, Japón
Nuevo
Doubleclick to zoom in
Contacte al vendedor
para más fotos y información.
Especificaciones
- Condición
- nuevo
- Additional function
- N/A
- Number of input units
- Max. 8 units
- Number of channels
- Max. 32 analog channels (when using the U8975), or 128 logic channels (when using the 8973)
- Measurement ranges (20 div full-scale)
- 10 mV to 400 V f.s., 12 ranges (when using the U8976), Resolution : 1/1600 of range 4 V to 200 V f.s., 6 ranges (when using the U8975), Resolution : 1/32000 of range
- Max. allowable input
- 1000 V DC / 700 V AC (when using the U8974), 200 V DC (when using the U8975), 400 V DC (when using the U8976)
- Frequency characteristics
- DC to 30 MHz (when using the U8976), DC to 2 MHz (when using the U8975)
- Max. sampling rate
- 200 MS/s, all channnels simultaneously (when using the U8976) External sampling: 10 MS/s
- Recording methods
- Normal: Normal waveform recording Envelope: Record maximum and minimum values every fixed period
- Storage memory capacity
- 1 G-words
- Removable storage
- SD memory card ×1, USB memory ×7, SSD/HDD (built in the main unit) ×1 FTP transmission (to LAN-connected computer) *Use only Storage Media sold by HIOKI.
- Display
- 12.1 inch XGA-TFT color LCD (1024 × 768 dots)
- External interfaces
- LAN, USB, SD, SATA, Monitor output
- Power supply
- 100 to 240 V AC (50/60 Hz) (300 VA max.)
- Dimensions and mass
- 353 mm (13.9 in)W × 235 mm (9.25 in)H × 154.8 mm (6.09 in)D, 6.5 kg (229.3 oz) (main unit only)
- Included accessories
- Power cord ×1, Quick start manual ×1, Operating Precautions ×1, Blank panel (for blank slots only)
- Categoría
- Osciloscopios en Japón
- Subcategoría
- Data acquisition (daq) for r&d and testing applications
- ID de Anuncio
- 61137845
Descripción
NO BLIND TIME. NO MISSED SIGNALS. Just uninterrupted real-time recording.
Oscilloscopes only begin recording when a trigger is activated, leaving gaps between captures. These blind intervals can hide fast, unpredictable events—voltage spikes, glitches, or timing faults—that are critical for diagnosis. Without full visibility, reliable analysis becomes impossible.
The MR6000’s Envelope mode samples at high speed but logs only the peak minimum and maximum values at a slower, user-defined rate. This approach captures transient events while minimizing file size and preserving long-term trends. Dual Sampling records both high-speed and low-speed data streams at once, with precise trigger control. Perfect for capturing detailed events while ensuring continuous, long-term monitoring.
Operate intuitively, respond instantly.
Capture fast events with 200MS/s isolated inputs.
Record long tests without worry — built-in high-capacity storage.