E6000 handheld three phase power quality and energy analyzer en Pekín, China
Nuevo
Doubleclick to zoom in
Contacte al vendedor
para más fotos y información.
Especificaciones
- Condición
- nuevo
- Voltage
- Rms, ava, pk+, pk-, rms-1/2, CF
- Frequency
- Freq
- Current
- Rms, ava, pk+, pk-, rms-1/2, CF
- Power & energy
- P, S, Q, PF, DPF, W
- Computing
- THD, DC, 1-50 Harm, 1-50 InHarm, 1-35 HiHarm, 1-50 SubHarm
- Voltage harmonic
- THD, DC, 1-50 Harm, 0-49 InHarm, 1-35 HiHarm, 1-50 SubHarm, KF
- Current harmonic
- THD, DC, 1-50 Harm
- Harmonic power
- Ia, Ib, Ic, ΣPtotal, ΣQtotal, ΣStotal, 15 minutes
- Fluctuation and flickering
- PST, PLT, Fluct, Fluct Max
- Unbal
- V Pos, A pos, V neg, A neg, V zero, A zero, Unbal
- Event log
- Voltage swell, voltage sags, DIP, surge current, voltage and current distortion out of limit, odd harmonics containing rate out of limited, unbalanced voltage current out of limit, frequency out of limit, PST out of limit, PLT out of limit, long-term voltage interruption, voltage fluctuation deviation
- Measurement types
- P Calculated by every 10 cyclesS Calculated by the effective value of voltage and currentQ Calculated by the apparent power, active power
- Display
- Table charts, trend charts
- Measuring range/resolution
- Voltage 120V/0.01V, 230V/0.01V, 400V/0.01V, 1000V/0.01V; Current according to the current clamps
- Measuring accuracy
- ±0.5%
- Measurement mode
- Swell When half-wave RMS of voltage is higher than set value and sustain time is 10ms-1min, judged as swell.Sags When half-wave RMS of voltage is lower than set value and sustain time is 10ms-1min, judged as sags. Sags When half-wave RMS of voltage is lower than set value and sustain time is 10ms-1min, judged as sags.DIP half-wave RMS of voltage is higher than set value and sustain time is 10ms-1min, judged as DIP
- Display mode
- Swell, sags, DIP wave sustain time, extent and so on.
- Accuracy
- 0.1% +accuracy of the current clamps
- Nominal frequency/resolution
- 50.000Hz/0.001Hz or 60.000Hz/0.001Hz
- Bandwidth measurement
- 42.5-57.5Hz or 52.5-67.5Hz
- Measurement accuracy
- 0.10%
- Measuring circuit
- 1P2W/2P3W/3P3W/3P4W
- Basic frequency of the measuring circuit
- 50Hz
- Input channels
- 4 phase voltage, 4 phase current
- Measurement range
- 0-20
- Measurement range/resolution
- -1.000-1.000/0.001
- Window points
- 5120 points every 10 cycles
- Number of measurement
- 1-50 Times
- Numbers of measurements
- 1-50 groups
- Measurement
- P short term (Pst), P long term (Plt)
- Size
- 8G
- Weight
- 2KG
- Voltage input
- 110V-240V
- Adapter output
- 15V, 3A
- Battery
- Rechargeable nickel metal hydride, 4500mAh
- Battery working time
- 4h
- Battery recharging time
- 5h (environment temperature 25°C)
- Power saving facility
- LCD backlight brightness is adjustable, standby time is adjustable
- Resolutions
- 640x480
- Brightness
- Max 350cd/m2 (Typ), brightness is adjustable
- Contrast
- 5001 (Typ)
- Visual angle
- 70/70/50/70 (Typ.)(CR≥10) (left/right/up/down)
- Measurement method
- IEC 61000-4-30
- Measurement performance
- IEC 61000-4-30 A LVL
- Flickering
- IEC 61000-4-15
- Harmonious
- IEC 61000-4-7
- Standard
- GB 4793.1-2007/IEC 61010-12001 "measurement, control and laboratory electrical equipment safety requirements", first part general requirements. Security level CAT III 1000V/CAT IV 600V.
- Max voltage of phase angle input
- CAT III 1000V/CAT IV 600V
- Working environment
- 0°C to +45°C, humidity below 90rh%
- Storage environment
- -20°C to +50°C, humidity below 95rh% (non-condensing)
- Categoría
- Analizadores de potencia en China
- Subcategoría
- Machinery
- Subcategoría 2
- Power-quality-analyzer
- ID de Anuncio
- 84813442
Descripción
E6000 handheld three phase power quality analyzer with CT offer the best ability in power quality analysis, E6000 handheld power quality analyzer help locate, predict, prevent and troubleshoot power quality problems in three phase and sing le phase power distribution systems.