HVS-30M-AXYZF Fully Automatic Vickers Hardness Tester en Jinan, Shandong, China
Nuevo
Doubleclick to zoom in
Contacte al vendedor
para más fotos y información.
Especificaciones
- Condición
- nuevo
- Item
- Automatic Micro Vickers Hardness Measuring Device HVS-5M-AXYZF
- Micro vickers hardness tester
- Model
- Test forces
- 0.3Kgf(2.94N)、0.5Kgf(4.9N)、1.0Kgf(9.8N)、2.0Kgf(19.6N)、3.0Kgf(29.4N)、5Kgf(49.0N)、10Kgf、20Kgf、30Kgf
- Carriage control
- Automatic Loading/Dwell/Unloading
- Focus
- Manual
- Eyepiece
- 10×
- Objective
- 10×、20×
- Max. measuring length
- 900um (100×), 230um (400×)
- Measuring range
- 1HV~2967HV
- Min. graduation value of test drum wheel
- 0.125μm、0.0625μm
- Precise bench vice
- Max. Open Size:50mm
- Turret
- Auto, Manual Objective—Indenter—Objective Auto Switch Rotation Auto Turret can provide rapid, easy operation array with no need of rotating turret by manual to realize the automatic switch of objective-indenter. The overlap accuracy error for center of objective and indenter is within 1μm, to ensure the accurate positioning of specimen indentation. Also, the center of objective can be adjustable and rotating the turret by manual is allowable.
- Loading speed
- 50mm/sec
- Dwell time
- 5-99sec
- Min. measuring unit
- 0.01mm
- Operation panel functions
- Membrane keyboard with high integrated PC board, LCD screen to clear display all the operation procedures, measuring conditions and measuring data- Operation Start/Reset/Dwell Time/Light Increase-Reduce/Light Source Switch/Conversion Scale/Turret Rotation (Auto)/Data Delete, Display D1/D2 Value/HV-HK Indication/Hardness Value/HRC Conversion Value/Measuring Times etc.
- Specimen stage
- 150×150mm Manual XY Location with Digital Display Accuracy of 1μm
- Ascending & descending of specimen stage
- By Manual
- Max. height of specimen
- 90mm(Auto Stage: 80mm)
- Max. width of specimen
- 110mm
- Parameters
- HV / HK
- Communication port
- RS232C
- Data output & print
- D1、D2、HV-HK Indication、Testing Force、Statistics etc.(Print after measurement or Print with measurement, single record or whole record print, three kinds of print style can be selectable.
- Optical function
- Flat field achromatic objective lens to make image more clearly, Field illumination can be adjustable, its illumination grades can be set from 0~9 of10kinds to meet different light requirements under different conditions
- Light source
- 12V50W According to specimen brightness, the light source can be controlled by computer to automatic adjust it to meet the optimal illumination.
- Accuracy conforms to
- JJG260-91、JIS B 7725、JIS B 7734、GB/T3430.2 -99 ASTM E-384、ISO 6507-2、ISO4546
- Hardness value conversion
- Conforms to GB1172-99 & ASTM Standard
- Dimensions (w×l×h)
- 196 × 450 × 468mm
- Weight
- Unit: 42kg(Including standard accessories)
- Power supply
- Single-phase 220V 50 Hz
- Ccd
- 1,300,000 pixel
- Computer
- Brand one with operation system of Windows XP
- Automatic x-y stage
- Drive Motor
- Drive control
- Movement in X-Y axis with flexible speed change through software
- Size
- 110 × 110mm
- Max. movement distance
- 50 ×50mm in X-Y directions
- Min. movement distance
- 1mm
- Movement speed
- 1-10mm/sec, Adjustable
- Displacement repeatability accuracy
- Within 1mm
- Set for stage movement
- Mouse click at any point in the interface to select the point automatically, initial location of the line and movement location at random can be set, mouse click to control the movement of 8 directions in the automatic XY stage, adjustable speed, automatic reset, coordinates 0 clear at random.
- Automatic measurement, control system
- System Descriptions
- Hardness tester control
- Automatic Control for Hardness Tester: Auto Turret (Objective-Indenter-Objective Auto Switch), Auto Loading, Auto Measurement Control; Light Source Illumination can be set; Select the switch of objective to reflect at the software port to calculate parameter change; Select or start hardness tester, the indenter switch to loading, dwell, unloading position automatically and rotate back to the objective position; The settings of loading by hardness tester can be reflected on the software interface.
- Control stage movement pattern
- The software system can control following automatic stage movements by program: 1)Measurement Mode(Random A) Indent and read any point by this mode. 2)Measurement Mode(Random B) Measure and read any point, rotate at any angle to position the coordinate’s location. 3) Indent and read in the horizontal direction (X direction). 4) Indent and read in the vertical direction (Y direction) 5)Measurement Mode(Line Set A) Indent and read the direction with a certain angle to the surface by this mode (Z-type movement, i.e. to measure the zigzag movement of hardened layer depth). 6)Measurement Mode(Line Set B) Indent and read with fixed spacing by this mode. 7)Trajectory coordinate movement mode 8 lines can be set at the same time and every line can be set 999 positions
- Measurement mode
- Auto mode: Auto Loading + Auto Measurement + Auto Display Testing Results Manual mode is selectable.
- Image collection/ recognition
- Use CCD camera with high quality, high resolution of 1,300,000 pixels, large size original image collection; Various kinds of image compression methods, easy to use (Image can be saved in BMP, JPG formats.) Use pixel recognition technology, analyze through special Vickers hardness indentation analysis software, which takes the technology of digital image processing and calculation method of boundary segmentation to extract the boundary of indentation; Then analyze the sample signal of testing indentation by Wavelet multi resolution theory; Fit the border line of indentation by least square method to extract the boundary of indentation and realize rapid and accurate extraction for the indentation area of micro Vickers hardness test, and calculate the Vickers hardness values automatically to improve the readability of unclear indentation on the unsmooth surface.
- Auto measurement time
- About 0.3sec/1 indentation
- Repeatability
- ±1.0% (700HV/500gf)
- Min. indentation
- About 5mm (Auto Measurement)
- Language
- English
- Data output format / edit function
- Inspection report can be customized as per user’s requirement. Hardened layer depth display in excel format can be generated after continuous measurement of specimens through data processing software. Measuring data, hardness values sheet, hardened layer depth, max. value, average value and min. value can be easily displayed and output as full-color image with hardness values. Hardness value, hardness sheet, hardened layer depth image and image insert can all be edited and printed including mathematical statistics and testing report of hardened layer depth, saved flexibly in “WORD” (“EXCEL” is selectable)/ The morphology diagram of specimen observed can be printed out and saved, the micro structure of indentation and background can be reflected directly, meanwhile, metallographic observation can be done under objectives with different magnifications.
- No.
- Quantity
- 1-1
- 1pc.
- 1-2
- 1pc.
- 1-3
- 2pcs.
- 1-4
- 1pc.
- 1-5
- 1pc.
- 1-6
- 1pc.
- 1-7
- 1pc.
- 1-8
- 4pcs.
- 1-9
- 1pc.
- 1-10
- 1pc.
- 1-11
- 1pc.
- 1-12
- 2pcs.
- 1-13
- 1pc.
- 1-14
- 1set.
- 1-15
- 1pc.
- 2
- 1set.
- 2-1
- 1pc.
- 2-2
- 1pc.
- 2-4
- 1pc.
- 2-5
- 1pc.
- 2-6
- 1set.
- 3-1
- 1pc.
- 3-2
- 1pc.
- Categoría
- Prueba de materiales en China
- Subcategoría
- Vicker hardness tester
- ID de Anuncio
- 87668946
Descripción
HVS-30M-AXYZF Fully Automatic Vickers Hardness Tester
Basic Structure
Digital Micro Vickers Hardness Tester with Auto Turret HV-5MD
HVS-M-AXYZF Auto Control, Measurement & Data Image Processing System
Main Applications
HVS-5M-AXYZF is mainly used for testing the Micro Vickers hardness of various kinds of ferrous or some of non-ferrous materials, spare parts (machining parts, forging parts, casting parts, steel casting parts), heat-treated parts, as well as effective hardened layer depth, coating or welding parts’ hardness of heat-effected location. It can also be used for observation of metal parts internal metallographic structure, collection, display and output print of images.
It is especially for measuring the hardness gradient distribution curve of work-pieces.
Main Functions
1. Automatic movement in Z axis and automatic focus.