6ES7635-2EC01-0AE3 C7-635 KEYS, 24 DI, 16 DO, 5 AI, 2 AO en Shenzhen, Guangdong, China

Especificaciones

Condición
nuevo
SIMATIC C7-635 KEYS, COMPACT UNIT WITH INTEGRATED COMPONENTS: S7-300 CPU314C-2 DP AND OP170B, 24 DI, 16 DO, 5 AI, 2 AO; MICRO MEMORY CARD AND CONNECTOR SET REQUIRED
Password protection
Yes
Password levels
10
Text elements
Yes
Info texts
Yes
Alarms
Yes
Graphics object
Yes
Number of process images
100
Number of variables per image, max.
50
Number of variables in message text, max.
8
Operating messages
Yes
Number of entries in operational log, max.
128; not retentive
Operating messages, max.
2000; total number of operation and fault messages
Alarm messages
Yes
Number of fault message, max.
2000; total number of operation and fault messages
Number of entries in fault message buffer, max.
128; not retentive
Number of recipes, max.
20
Data records per recipe, max.
50; limited due to storage medium
Entries per data record, max.
60
Recipe data memory, max.
32 kbyte; expandable using Compact Flash Card (CF-Card)
Design of display
STN, CCFL backlit, 5.7" blue mode (4 blue tones)
Horizontal image resolution
320
Vertical image resolution
240
Mtbf backlighting (at 20 °c)
50000 h
Number of operating cycles, keys
1000000
Number of function keys
10
Number of softkeys
14
24 v dc
Yes
Permissible range, lower limit (dc)
20.4 V
Permissible range, upper limit (dc)
28.8 V
Rated value (dc)
24 V
Current consumption, typ.
350 mA; idling
Current consumption, max.
1 A
Inrush current, max.
2 A; for 70 ms
From load voltage l (without load), max.
70 mA
From load voltage l , max.
20 mA; per group
Power loss, typ.
14 W
Micro memory card
Yes
Compact flash card
Yes; Optional
Integrated
1
Expandable
No
Plug-in (mmc)
Yes
Plug-in (mmc), max.
8 Mbyte
Present
Yes
For bit operations, typ.
0.1 µs
For word operations, typ.
0.2 µs
For fixed point arithmetic, typ.
2 µs
For floating point arithmetic, typ.
3 µs
Number, max.
511
Size, max.
16 kbyte
Per priority class
8
Additional within an error ob
4
Number
1
Adjustable
No
Preset
No retentivity
Lower limit
48 Ω
Upper limit
4 kΩ
Retentive data area in total (incl. times, counters, flags), max.
all
Retentivity available
Yes
Retentivity preset
MB 0 to MB 15
Number of clock memories
8; 1 memory byte
Per priority class, max.
510 byte
Inputs
244 byte
Outputs
244 byte
Inputs, of which central
248
Outputs, of which central
248
Number of modules per system, max.
23
Via cp
1
Fm
8
Cp, point-to-point
8
Cp, lan
10
Racks, max.
4
Modules per rack, max.
4; 4 in subrack 0; 8 in subracks 1 and 2; 7 in subrack 3
Hardware clock (real-time clock)
Yes
Battery-backed and synchronizable
Yes
Deviation per day, max.
10 s
Backup time
6 wk; At 40 °C ambient temperature
Number/number range
0
Range of values
0 to 2^31 hours (when using SFC 101)
Granularity
1 hour
Retentive
Yes; Must be restarted at each restart
Supported
Yes; Via CP and loadable FB
To mpi, master
Yes
To mpi, slave
Yes
In as, master
Yes
Number of digital inputs
24
Of which inputs usable for technological functions
16
Integrated channels (di)
24
Input characteristic curve in accordance with iec 61131, type 1
Yes
Up to 40 °c, max.
3 A
Up to 50 °c, max.
2 A
Up to 45 °c, max.
2 A
Rated value, dc
24 V
For signal "0"
-3 to 5 V
For signal "1"
15 to 30 V
For signal "1", typ.
7 mA
Parameterizable
Yes; by software
Rated value
3 ms
At "0" to "1", max.
8 µs
Cable length, shielded, max.
200 m
Cable length unshielded, max.
600 m
Shielded, max.
1000 m
Unshielded, max.
600 m
Number of digital outputs
16
Of which high-speed outputs
4
Integrated channels (do)
16
Short-circuit protection
Yes; Clocked electronically
Response threshold, typ.
1 A
Limitation of inductive shutdown voltage to
L (-48 V)
Controlling a digital input
Yes
Lamp load, max.
5 W
For signal "1", min.
L (-0.8 V)
For signal "1" rated value
0.5 A
For signal "1" permissible range, min.
5 mA
For signal "1" permissible range, max.
0.6 A
For signal "1" minimum load current
5 mA
For signal "0" residual current, max.
0.5 mA
For uprating
No
For redundant control of a load
Yes
With resistive load, max.
100 Hz
With inductive load, max.
0.5 Hz
On lamp load, max.
100 Hz
Of the pulse outputs, with resistive load, max.
2.5 kHz
Up to 60 °c, max.
2 A
Integrated channels (ai)
4; and 1x PT100
Number of analog inputs
4
Number of analog inputs for voltage/current measurement
4
Number of analog inputs for resistance/resistance thermometer measurement
1
Number of analog inputs for resistance measurement
1
Permissible input voltage for current input (destruction limit), max.
2.5 V; continuous, max. 24 V momentarily
Permissible input voltage for voltage input (destruction limit), max.
30 V; Permanent
Permissible input current for voltage input (destruction limit), max.
0.5 mA; Permanent
Permissible input current for current input (destruction limit), max.
50 mA; Permanent
Technical unit for temperature measurement adjustable
Yes; Degrees Celsius / degrees Fahrenheit / Kelvin
Voltage
Yes
Current
Yes
Resistance thermometer
Yes
Resistance
Yes
0 to 10 v
Yes
Input resistance (0 to 10 v)
100 kΩ
10 v to 10 v
Yes
Input resistance (-10 v to 10 v)
100 kΩ
0 to 20 ma
Yes
Input resistance (0 to 20 ma)
50 kΩ
20 to 20 ma
Yes
Input resistance (-20 to 20 ma)
50 kΩ
4 to 20 ma
Yes
Input resistance (4 to 20 ma)
50 kΩ
Pt 100
Yes
Input resistance (pt 100)
10 MΩ
No-load voltage, typ.
2.5 V
Measured current, typ.
1.8 to 3.3 mA
0 to 600 ohm
Yes
Input resistance (0 to 600 ohm)
10 MΩ
For resistance thermometer
Pt 100
Integrated channels (ao)
2
Number of analog outputs
2
Voltage output, short-circuit protection
Yes
Voltage output, short-circuit current, max.
55 mA
Current output, no-load voltage, max.
17 V
10 to 10 v
Yes
For voltage output two-wire connection
Yes; Without compensation of the line resistances
For voltage output four-wire connection
No
For current output two-wire connection
Yes
With voltage outputs, min.
1 kΩ
With voltage outputs, capacitive load, max.
0.1 µF
With current outputs, max.
300 Ω
With current outputs, inductive load, max.
0.1 mH
Voltages at the outputs towards mana
16 V; Permanent
Current, max.
50 mA; Permanent
Measurement principle
Actual value encryption (successive approximation)
Resolution with overrange (bit including sign), max.
12 bit
Integration time, parameterizable
Yes; 2,5 / 16,6 / 20 ms
Permissible input frequency, max.
400 Hz
Conversion time (per channel)
1 ms
Time constant of the input filter
0.38 ms
Basic execution time of the module (all channels released)
1 ms
For resistive load
0.6 ms
For capacitive load
1 ms
For inductive load
0.5 ms
For voltage measurement
Yes
For current measurement as 2-wire transducer
Yes; with external supply
For current measurement as 4-wire transducer
Yes
For resistance measurement with two-wire connection
Yes; Without compensation of the line resistances
For resistance measurement with three-wire connection
No
For resistance measurement with four-wire connection
No
2-wire sensor
Yes
Permissible quiescent current (2-wire sensor), max.
1.5 mA
Linearity error (relative to input range), ( /-)
0.06 %
Temperature error (relative to input range), ( /-)
0.0060 %/K
Crosstalk between the inputs, min.
50 dB
Repeat accuracy in steady state at 25 °c (relative to input area), ( /-)
0.06 %
Linearity error (relative to output range), ( /-)
0.15 %
Temperature error (relative to output range), ( /-)
0.01 %/K
Crosstalk between the outputs, min.
60 dB
Voltage, relative to input area, ( /-)
0.7 %
Current, relative to input area, ( /-)
0.7 %
Resistance, relative to input area, ( /-)
3 %
Voltage, relative to output area, ( /-)
0.7 %
Current, relative to output area, ( /-)
0.7 %
Resistance thermometer, relative to input area, ( /-)
3 %
Series mode interference (peak value of interference < rated value of input range), min.
30 dB
Common mode interference, min.
40 dB
Number of printer interfaces
1; serial
Interface type
Integrated RS 485 interface
Physics
RS 485
Isolated
Yes
Power supply to interface (15 to 30 v dc), max.
200 mA
Mpi
No
Transmission rate, max.
12 Mbit/s
Pg/op communication
Yes
Routing
Yes; Only with active interface
S7 communication, as client
No
S7 communication, as server
No
Number of connection resources
12
Number of connections, max.
12
Number of connections (of which reserved), max.
1 for PG, 1 for OP
Number of dp slaves, max.
32
Equidistance mode support
Yes
Sync/freeze
Yes
Activation/deactivation of dp slaves
Yes
Direct data exchange (slave-to-slave communication)
Yes
Inputs, max.
244 byte
Outputs, max.
244 byte
Address area, max.
32
User data per address area, max.
32 byte
Dpv1
No
Number of gd packets, max.
4
Number of gd packets, transmitter, max.
4
Number of gd packets, receiver, max.
4
Size of gd packets, max.
22 byte
Size of gd packet (of which consistent), max.
22 byte
User data per job, max.
180 kbyte; With PUT/GET
User data per job (of which consistent), max.
64 byte
As server
Yes
As client
Yes; Via CP and loadable FB
Overall
12
Usable for pg communication
11
Reserved for pg communication
1
Adjustable for pg communication, min.
1
Adjustable for pg communication, max.
11
Usable for op communication
11
Reserved for op communication
1
Adjustable for op communication, min.
1
Adjustable for op communication, max.
11
Usable for s7 basic communication
8
Reserved for s7 basic communication
8
Adjustable for s7 basic communication, min.
0
Adjustable for s7 basic communication, max.
8
Usable for routing
4
Number of logical connections (also in network), max.
4; 1 fixed with integral CPU
Number of login stations for message functions, max.
12; Depending on the configured connections for PG/OP and S7 basic communication
Process diagnostic messages
Yes
Simultaneously active alarm-s blocks, max.
40
Status block
Yes
Single step
Yes
Number of breakpoints
2
Status/control variable
Yes
Variables
Inputs, outputs, memory bits, DB, times, counters
Number of variables, max.
30
Of which status variables, max.
30
Of which control variables, max.
14
Forcing
Yes
Number of entries, max.
100
Number of counters
4
Counting frequency (counter) max.
60 kHz
Frequency measurement
Yes
Number of frequency meters
Frequency meter up to max. 60 kHz
Controlled positioning
Yes
Integrated function blocks (closed-loop control)
Yes; PID controller
Pid controller
Yes
Number of pulse outputs
4; Pulse outputs up to 2.5 kHz
Limit frequency (pulse)
2.5 kHz
Between the channels
No
Between the channels, in groups of
8
Between the channels and the backplane bus
Yes
Galvanic isolation analog inputs
Yes; common for analog I/O
Galvanic isolation analog outputs
Yes; common for analog I/O
Between different circuits
75 VDC / 60 VAC
Between inputs and mana (ucm)
8 V DC
Between mana and m internally (uiso)
75 VDC / 60 VAC
Isolation tested with
500 V DC
Interference immunity against discharge of static electricity acc. to iec 61000-4-2
Yes; ±6 kV contact discharge acc. to IEC 61000-4-2, ESD; ±8 kV air discharge acc. to IEC 61000-4-2, ESD
On the supply lines acc. to iec 61000-4-4
Yes
Interference immunity on signal cables acc. to iec 61000-4-4
Yes; ±2 kV to IEC 61000-4-4, Burst
On the supply lines acc. to iec 61000-4-5
Yes; Surge measurements with additional protection elements: ±1 kV (to IEC 61000-4-5; µs pulse / line to line);±2 kV (to IEC 61000-4-5; µs pulse / line to ground)
Interference immunity against high-frequency radiation acc. to iec 61000-4-3
Yes; 10 V/m, with 80% amplitude modulation at 1 kHz, 80 MHz to 1 GHz (to IEC 61000-4-3); 10 V/m, pulse-modulated 50% duty cycle at 900 MHz and 1.89 GHz (to IEC61000-4-3)
Interference immunity against high-frequency radiation acc. to iec 61000-4-6
Yes; 10 V/m, with 80% amplitude modulation at 1 kHz, 10 kHz to 80 MHz (acc. to IEC 61000-4-6)
Emission of radio interference acc. to en 55 011 (limit class a)
Yes
Ip20
Yes; Housing
Ip65
Yes; Front
Csa approval
Yes
Ul approval
Yes
Fm approval
Yes
Environmental conditions
Not suitable for open-air use
45 degree installation, min.
0 °C
45 degree installation, max.
45 °C
Horizontal installation, min.
0 °C
Horizontal installation, max.
40 °C
Vertical installation, min.
0 °C
Vertical installation, max.
50 °C
Min.
-20 °C
Max.
70 °C
Operation, min.
5 %
Operation, max.
95 %
Storage/transport, min.
5 %
Storage/transport, max.
95 %
Operation, tested according to iec 60068-2-6
Yes; 10 to 58 Hz: Amplitude 0.075 mm; 58 to 150 Hz: Acceleration 9.8 m/s2
Transport, tested acc. to iec 60068-2-6
Yes; 5 to 9 Hz: amplitude 3.5 mm; 9 to 500 Hz: acceleration 9.8 m/s (storage/transport in the packaging)
Tested according to iec 60068-2-27
Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms
Operation, tested according to iec 60068-2-29
Yes; Half-sine: 150 m/s2 (15 g), 11 ms, 18 shocks
Storage/transport, tested acc. to iec 60068-2-29
Yes; 250 m/s2 (25 g), 6 ms, 1000 shocks
Terminal strips
FV2 (tested to IEC 60707)
Basic strips in housing
FV0
Step 7
Yes; V5.1 SP3, STEP 7 Lite
Protool
Yes; or SIMATIC ProTool/Pro Configuration, Version 6.0 SP1 or higher
Protool/lite
Yes
Protool/pro
Yes; Configuration also with WinCC flexible
Wincc flexible compact
Yes
Wincc flexible standard
Yes
Wincc flexible advanced
Yes
Command set
see instruction list
Nesting levels
8
System functions (sfc)
see instruction list
System function blocks (sfb)
see instruction list
Lad
Yes
Fbd
Yes
Stl
Yes
Scl
Yes
Cfc
Yes
Graph
Yes
Higraph®
Yes
User program protection/password protection
Yes
Number of online/runtime languages
3
Width
260 mm
Height
274 mm
Depth
80 mm
Mounting cutout, width
231 mm
Mounting cutout, height
257 mm
Weight, approx.
1500 g
Subcategoría
Plc
Subcategoría 2
Siemens plc all
Subcategoría 3
C7/rack pc,box pc
ID de Anuncio
88362508

Descripción

SIEMENS C7/RACK PC,BOX PC 6ES76352EC010AE3 SIMATIC C7-635 KEYS,,COMPACT UNIT,WITH INTEGRATED COMPONENTS:,S7-300 CPU314C-2 DP AND OP170B,,24 DI, 16 DO, 5 AI, 2 AO;,MICRO MEMORY CARD AND,CONNECTOR SET REQUIREDSIMATIC C7-635 TASTEN,,KOMPLETTGERAET,MIT INTEGR

Contactar al vendedor

Fabricante
N/A
Modelo
6ES7635-2EC01-0AE3
Ubicación
🇨🇳 Shenzhen, Guangdong, China