Building Filters

CHEMICAL IMPEDANCE ANALYZER IM3590
Measurement modes: LCR mode, Continuous measurement mode (LCR mode / Analyzer mode), Analyzer mode (Sweeps with measurement frequency and measurement level, temperature characteristics, equivalent circuit analysi...
Nagano, Japón
Yamato BL401
- Fabricante: Yamato
Method: Pump circulating cooling | Operating temperature range: -15~+70°C | Temperature control accuracy: ±0.1°C | Temperature distribution accuracy: ±0.3°C | Temperature indicating unit: 0.1°C | Cooling capacity...
Tokio, Japón
Yamato HF200
- Fabricante: Yamato
Operating temp. range: Room temp. +5 to 200℃ | Temp. adjustment accuracy: ±0.2℃ (at 200℃ , at using φ16.5 testing tube) | Time to reach to max. temp.: Approx. 35min. (Room temp. 23℃ ) | Loadable block: Aluminium ...
Tokio, Japón
Yamato HF100
- Fabricante: Yamato
Operating temp. range: Room temp. +5 to 200℃ | Temp. adjustment accuracy: ±0.2℃ (at 200℃ , at using φ16.5 testing tube) | Time to reach to max. temp.: Approx. 30min. (Room temp. 23℃ ) | Loadable block: Aluminium ...
Tokio, Japón
POWER ANALYZER PW6001
Measurement line type: Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, three-phase 4-wire | Number of input channels: Max. 6 channels; each input unit provides 1 channel for simultaneous voltage and...
Nagano, Japón
Yamato BL810
- Fabricante: Yamato
Method: Pump circulating cooling | Operating temperature range: -15~+70°C | Temperature control accuracy: ±0.1°C | Temperature distribution accuracy: ±0.3°C | Temperature indicating unit: 0.1°C | Cooling capacity...
Tokio, Japón
Yamato ADL311-A
- Fabricante: Yamato
Temp. adjusting unit setting range: 40 to 220deg.C (inlet temperature), 0 to 60deg.C (outlet temperature) | Temperature adjusting accuracy: Inlet temperature±1deg.C | Drying air amount adjusting range: 0〜0.7m3/mi...
Tokio, Japón
Yamato DKG810
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30°C to 260°C | Temperature adjustment accuracy: ±0.5℃ | Temperature distribution accuracy: ±2℃(at 200℃)、±2.5℃(at 260℃) | Time to attain max. t...
Tokio, Japón
Yamato DKG650V
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30°C to 260°C | Temperature adjustment accuracy: ±0.5℃ | Temperature distribution accuracy: ±2℃(at 200℃)、±2.5℃(at 260℃) | Time to attain max. t...
Tokio, Japón
Yamato DKG650
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30°C to 260°C | Temperature adjustment accuracy: ±0.5℃ | Temperature distribution accuracy: ±2℃(at 200℃)、±2.5℃(at 260℃) | Time to attain max. t...
Tokio, Japón
Yamato DKG810V
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30°C to 260°C | Temperature adjustment accuracy: ±0.5℃ | Temperature distribution accuracy: ±2℃(at 200℃)、±2.5℃(at 260℃) | Time to attain max. t...
Tokio, Japón
Yamato DKG610V
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30°C to 260°C | Temperature adjustment accuracy: ±0.5℃ | Temperature distribution accuracy: ±2℃(at 200℃)、±2.5℃(at 260℃) | Time to attain max. t...
Tokio, Japón
GENNECT ONE SF4000
- Fabricante: HIOKI E.E
Functions: Automatically send files saved by LAN-connected instruments to a computer. | Storage size: Trial: 512MB, Free: 5GB, Standard: 50GB, Pro: 500GB | Supported models (remote measurement mode): PQ3100, PQ31...
Nagano, Japón
HORIBA Advanced Techno Co., Ltd. 5700A
- Fabricante: Horiba
Measuring method: Optical (fluorescent) | Measuring range: DO: 0 to 20 mg/L Resolution: 0.01 mg/L Saturation: 0 to 200% Resolution: 0.1% Temperature: 0 to 50°C Resolution: 0.1°C | Transmission output: 2...
Kioto, Japón
HEAT FLOW LOGGER LR8432
Specialized functions for heat flow measurement: - Easy scaling settings: directly enter the sensitivity of the heat flow sensor - Calculations: waveform processing function for the analysis of temperature and he...
Nagano, Japón