Building Filters

Yamato DN411I
- Fabricante: Yamato
Method: Forced Convection | Operating temp. range: Room Temp. +15 to 360°C | Temp. adjustment accuracy: ±0.2℃(at 360℃) | Temp. fluctuation: 1.2℃(at 360℃) | Temp. uniformity: ±3℃(at 360℃) | Temp. gradient: 12℃(at ...
Tokio, Japón
Yamato DN611I
- Fabricante: Yamato
Method: Forced Convection | Operating temp. range: Room Temp. +15 to 360°C | Temp. adjustment accuracy: ±0.2℃(at 360℃) | Temp. fluctuation: 1.2℃(at 360℃) | Temp. uniformity: ±3℃(at 360℃) | Temp. gradient: 20℃(at ...
Tokio, Japón
Yamato FP102
- Fabricante: Yamato
Operating temp. range: 100~1,150℃ | Temp. control accuracy: ±1.0℃(at 1150℃) | Temp. fluctuation: 2.0℃(at 1150℃) | Temp. distribution: ±4.0℃(at 1150℃) | Temp. gradient: 14℃(at 1150℃) | Max. temp. reaching time: Ap...
Tokio, Japón
Yamato CLH610
- Fabricante: Yamato
Method: External opened circulation | Operating temperature range: -15 to +80°C | Temperature control accuracy: ±0.1°C (JTM K05) at fluid temp.10°C | Cooling capacity: Approx. 785W (676 Kcal/h), at fluid temp.15°...
Tokio, Japón
Yamato CLH302
- Fabricante: Yamato
Method: External opened circulation | Operating temperature range: -10 to +80°C | Temperature control accuracy: ±0.1°C (JTM K05) at fluid temp.10°C | Cooling capacity: Approx. 450W (387Kcal/h), at fluid temp.15°C...
Tokio, Japón
Yamato CLH401
- Fabricante: Yamato
Method: External opened circulation | Operating temperature range: -15 to +80°C | Temperature control accuracy: 0.2°C (JTM K05/JIS) at fluid temp.10°C | Cooling capacity: Approx. 600W (517 Kcal/h), at fluid temp....
Tokio, Japón
Yamato WE200
- Fabricante: Yamato
Purified water: Deionized water: JIS K0057 A4 | Water purifying method: RO membrane→Ion exchange→filtration | Pure water delivery rate: 0.5 to 1.0L/min continuous production | Raw water filter: Pre-treatment cart...
Tokio, Japón
Yamato DF832
- Fabricante: Yamato
Fan motor: Axial flow fan (capacitor motor: 20W) | Cable port: I.D. ø30mm (rear) | Heat insulator: Glass wool | Other additional structure: Exhaust damper (manual operation) | Safety device: Self-diagnostic funct...
Tokio, Japón
Yamato DNE911
- Fabricante: Yamato
- Modelo: DNE911
Operating temp. range: Room temp. +15 to 210°C | Temp. adjustment accuracy: ±0.5°C (at 210°C) | Temp. distribution accuracy: ±2.0°C (at 210°C) | Max. temp. reaching time: Approx. 60 min. | Interior/exterior mater...
Tokio, Japón
Yamato DNE611
- Fabricante: Yamato
Operating temp. range: Room temp. +20 to 210°C | Temp. adjustment accuracy: ±0.5°C (at 210°C) | Temp. distribution accuracy: ±2.0°C (at 210°C) | Max. temp. reaching time: Approx. 70 min. | Interior/exterior mater...
Tokio, Japón
Yamato DNE601
- Fabricante: Yamato
Operating temp. range: Room temp. +20 to 210°C | Temp. adjustment accuracy: ±0.5°C (at 210°C) | Temp. distribution accuracy: ±2.0°C (at 210°C) | Max. temp. reaching time: Approx. 70 min. | Interior/exterior mater...
Tokio, Japón
Yamato DNE811
- Fabricante: Yamato
- Modelo: DNE811
Operating temp. range: Room temp. +15 to 210°C | Temp. adjustment accuracy: ±0.5°C (at 210°C) | Temp. distribution accuracy: ±2.0°C (at 210°C) | Max. temp. reaching time: Approx. 45 min. | Interior/exterior mater...
Tokio, Japón
Yamato DNE401
- Fabricante: Yamato
- Modelo: DNE401
Operating temp. range: Room temp. +20 to 210℃ | Temp. adjustment accuracy: ±0.5°C (at 210°C) | Temp. distribution accuracy: ±2.0°C (at 210°C) | Max. temp. reaching time: Approx. 60 min. | Interior/exterior materi...
Tokio, Japón
Yamato DNE411
- Fabricante: Yamato
Operating temp. range: Room temp. +20 to 210°C | Temp. adjustment accuracy: ±0.5°C (at 210°C) | Temp. distribution accuracy: ±2.0°C (at 210°C) | Max. temp. reaching time: Approx. 60 min. | Interior/exterior mater...
Tokio, Japón
Yamato DKN812
- Fabricante: Yamato
Circulation method: Forced air circulation | Operating temp. range: Room temp. +10°C to 210°C | Temp. adjustment accuracy: ±1℃(at 210℃) | Temp. distribution accuracy: ±2.5℃(at 210℃) | Max. temp. reaching time: Ap...
Tokio, Japón