Yamato FP413
- Fabricante: Yamato
- Modelo: FP413
- Fuente de alimentación: Electric
Operating temp. range: 100~1,150℃ | Temp. control accuracy: ±1.0℃(at 1150℃) | Temp. fluctuation: 2.0℃(at 1150℃) | Temp. distribution: ±4.0℃(at 1150℃) | Temp. gradient: 14℃(at 1150℃) | Max. temp. reaching time: Ap...
Tokio, JapónYamato DKM400
- Fabricante: Yamato
Circulation method: Forced air circulation | Operating temperature range: Room temp. +10~260°C | Temp. control accuracy: ±1°C (at 210°C) | Temp. distribution accuracy: ±2.5℃(at 210℃) | Max. temp. reaching time: A...
Tokio, JapónYamato SI402
- Fabricante: Yamato
Circulation method: Natural convection (for laboratory use only) | Operating temp. range: Room temp. +5~260°C | Temp. adjustment accuracy: JTM K05 ±1°C (at 260°C) | Temp. distribution accuracy: JTM K05 ±6°C (at 2...
Tokio, JapónYamato FP313
- Fabricante: Yamato
- Fuente de alimentación: Electric
Operating temp. range: 100~1,150℃ | Temp. control accuracy: ±1.0℃(at 1150℃) | Temp. fluctuation: 2.0℃(at 1150℃) | Temp. distribution: ±4.0℃(at 1150℃) | Temp. gradient: 14℃(at 1150℃) | Max. temp. reaching time: Ap...
Tokio, JapónYamato DKM300
- Fabricante: Yamato
Circulation method: Forced air circulation | Operating temperature range: Room temp. +10~260°C | Temp. control accuracy: ±1°C (at 210°C) | Temp. distribution accuracy: ±2.5℃(at 210℃) | Max. temp. reaching time: A...
Tokio, JapónYamato DKM600
- Fabricante: Yamato
Circulation method: Forced air circulation | Operating temperature range: Room temp. +10~260°C | Temp. control accuracy: ±1°C (at 210°C) | Temp. distribution accuracy: ±2.5℃(at 210℃) | Max. temp. reaching time: A...
Tokio, JapónYamato IN804
- Fabricante: Yamato
- Modelo: IN804
System: Forced air convection | Operating temperature range: -10~50℃ | Temperature adjustment accuracy: ±0.3℃(when refrigerator is in continuous operation), ±1.0℃(when refrigerator is in cycle operation) | Temper...
Tokio, JapónYamato IN604
- Fabricante: Yamato
System: Forced air convection | Operating temperature range: -10~50℃ | Temperature adjustment accuracy: ±0.3℃(when refrigerator is in continuous operation), ±1.0℃(when refrigerator is in cycle operation) | Temper...
Tokio, JapónYamato IQ822
- Fabricante: Yamato
System: Forced Convection | Operating temperature range: -10~+50℃ | Temperature adjustment accuracy: ±0.3℃(During continuous refrigeration for both upper and lower chamber) | Temperature distribution accoracy: ±1...
Tokio, JapónYamato DT300
- Fabricante: Yamato
Method: Forced air circulation | Operating temp. range: Room temp. +20°C to 300°C | Temp. control accuracy (jtm k05): ±0.3℃(at 100℃, 200℃, 300℃) | Temp. fluctuation (jis): 1.0°C (at 100 / 200°C) , 2.0°C (at 300°C...
Tokio, JapónYamato IN604W
- Fabricante: Yamato
System: Forced air convection | Operating temperature range: -10~50℃ | Temperature adjustment accuracy: ±0.3℃(when refrigerator is in continuous operation), ±1.0℃(when refrigerator is in cycle operation) | Temper...
Tokio, JapónYamato DVS603
- Fabricante: Yamato
Method: Natural gravity convection | Operating temp. range: Room temp.+5~260℃ | Temp. control accuracy: ±1℃(at 260℃) | Temp. distribution accuracy: ±5℃(at 260℃) | Max. temp. reaching time: Approx. 90 min. | Inter...
Tokio, JapónYamato DT411
- Fabricante: Yamato
Temp. distribution accuracy: ±4.0°C (at 360°C) JTM K05 | Max. temp. reaching time: Approx. 80 min. (at 360°C) | Heater: Stainless pipe heater | Cable hole: 33mm I.D. ×1 | Timer: 1 min. to 99 Hrs. 59 min | Operati...
Tokio, JapónYamato DE411
- Fabricante: Yamato
Temp. distribution accuracy: ±2.5°C (at 260°C) JTM K05 | Max. temp. reaching time: Approx. 70 min. (at 260°C) | Heater: Stainless pipe heater | Cable hole: 33mm I.D. ×1 | Timer: 1 min. to 99 Hrs. 59 min | Operati...
Tokio, JapónYamato DT300H
- Fabricante: Yamato
Method: Forced air circulation | Operating temp. range: Room temp. +20°C to 300°C | Temp. control accuracy (jtm k05): ±0.3℃(at 100℃, 200℃, 300℃) | Temp. fluctuation (jis): 1.0°C (at 100 / 200°C) , 2.0°C (at 300°C...
Tokio, Japón