Building Filters

Yamato CIW1100
- Fabricante: Yamato
Circulation method: External closed system circulation | Cooling method: Water-cooled type | Temperature control range: 0 - 80℃ (Operation of entire freezer) | Operating temperature range: 5 - 35℃ | Temp. adjustm...
Tokio, Japón
Yamato IQ822
- Fabricante: Yamato
System: Forced Convection | Operating temperature range: -10~+50℃ | Temperature adjustment accuracy: ±0.3℃(During continuous refrigeration for both upper and lower chamber) | Temperature distribution accoracy: ±1...
Tokio, Japón
CLAMP ON POWER LOGGER PW3360
- Fabricante: HIOKI E.E
Measurement line & number of circuits: 50/60 Hz, Single phase 2 wires (1/2/3 circuits), Single phase 3 wires (1 circuit), Three phases 3 wires (1 circuit), Three phases 4 wires (1 circuit), Current only: 1 to 3 c...
Nagano, Japón
HORIBA Advanced Techno Co., Ltd. HD-200
- Fabricante: Horiba
Product name: Dissolved oxygen converter | Combined sensor: 5505, 5510 (A bipolar diaphragm type polarography sensor) | Combined probe: DO-1100 | Saturation degree: 1% | Temperature: 0.1℃ | Linearity: Within ±0.0...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. HD-300
- Fabricante: Horiba
Product name: Dissolved oxygen meter | Combined sensor: 5505, 5510 (A bipolar diaphragm type polarography sensor) | Combined probe: DO-1100 | Saturation degree: 1% | Temperature: 0.1℃ | Linearity: Within ±0.08 mA...
Kioto, Japón
HORIBA Scientific VU90 Spectrometer
- Fabricante: Horiba
Spectral coverage: 115 - 230 nm Full coverage on CCD: 115 - 320 nm (No order sorting filter available) | Spectral resolution: 0.5 nm with 22 μm pinhole, 0.75 nm with 40 μm pinhole | Spectral dipersion: 12 nm/mm; ...
Kioto, Japón
HORIBA, Ltd. VA-5000 / VA-5000WM Series
- Fabricante: Horiba
Communication: Ethernet (ModbusTM/TCP) | Output: Maximum 16ch isolated, Maximum voltage DC 30 V, Maximum current 1A Minimum voltage DC 0.1 V, Minimum current 0.1 mA | Sample condition: Ambient temperature, dust f...
Kioto, Japón
HORIBA Scientific PoliSpectra® Quad
- Fabricante: Horiba
Spectral coverage: Tunable from 470 to 730 nm | Spectrometer input: FC (standard), other input types available upon request | Spectral resolution: 2.7 nm with 75 µm slit; 5 nm for Ø 200 µm fiber (no slit) |...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. CS-900
- Fabricante: Horiba
Model name: Non-contact type chemical concentration monitor | Measurement method: Absorption spectroscopy | Concentration calculation: Temperature compensated multivariate analysis | Conditions of measurement: 1)...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. HC-200F
- Fabricante: Horiba
Product name: Fluoride ion meter | Electrode used with product: Fluoride ion electrode | Temperature: 0.1℃ | Linearity: Within ±0.08 mA (output only) | Output type: Contact output with voltage (output of connecte...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. HE-200H
- Fabricante: Horiba
Product name: Conductivity meter | Sensors in combination: 4-electrode method conductivity sensor (FES Series) of cell constant 0.1/cm, or 1.0/cm | Display range: 0.0 to 220.0 | Temperature: 0.01℃ | Nacl: 0.0% to...
Kioto, Japón
60cm UV DTF Printer with I3200 Crystal Sticker Printing
Product name: 60 UV DTF Printer | Nozzle type: XP600/I1600/I3200 | Speed: 720*720 4pass 7m²/H | Color configuration: KCMYLCLM+W+V+GV; Effective Printing Width; 60CM | Power: 1500w; Equipment Size; 1620*860*1510 m...
Cantón, China
Yamato IN604
- Fabricante: Yamato
System: Forced air convection | Operating temperature range: -10~50℃ | Temperature adjustment accuracy: ±0.3℃(when refrigerator is in continuous operation), ±1.0℃(when refrigerator is in cycle operation) | Temper...
Tokio, Japón
Yamato INC820
- Fabricante: Yamato
System (upper chamber): Natural convection, Air jacket | Operating temp. range(upper chamber): Room temp.+5℃~80℃ | Temp. adjustment accuracy (upper chamber): ±0.5℃(at 37℃) | Temp. distribution accuracy (upper cha...
Tokio, Japón
Yamato IN604W
- Fabricante: Yamato
System: Forced air convection | Operating temperature range: -10~50℃ | Temperature adjustment accuracy: ±0.3℃(when refrigerator is in continuous operation), ±1.0℃(when refrigerator is in cycle operation) | Temper...
Tokio, Japón