Building Filters
Yamato FP413
- Fabricante: Yamato
- Modelo: FP413
Operating temp. range: 100~1,150℃ | Temp. control accuracy: ±1.0℃(at 1150℃) | Temp. fluctuation: 2.0℃(at 1150℃) | Temp. distribution: ±4.0℃(at 1150℃) | Temp. gradient: 14℃(at 1150℃) | Max. temp. reaching time: Ap...
Tokio, JapónYamato WG511
- Fabricante: Yamato
Water purifying method: Ion exchange→Distillation→Filtration | Sampled pure water method: One-touch coupler connecting resin hose / free hose connecting | Distilled water production: Left / right selection for co...
Tokio, JapónHORIBA Advanced Techno Co., Ltd. 5700A
- Fabricante: Horiba
Measuring method: Optical (fluorescent) | Measuring range: DO: 0 to 20 mg/L Resolution: 0.01 mg/L Saturation: 0 to 200% Resolution: 0.1% Temperature: 0 to 50°C Resolution: 0.1°C | Transmission output: 2...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HP-200
- Fabricante: Horiba
Product name: pH meter | Combined sensor: Glass electrode | Temperature: 0.1℃ | Linearity: Within ±0.08 mA (output only) | Output type: AC power control output (applied power supply voltage) | Load resistance: Ma...
Kioto, JapónYamato SK401
- Fabricante: Yamato
Circulation method: Natural convection | Temp. setting range: Room temp. +5~260°C | Temp. control accuracy: ±1℃(at 260℃)JTM K05 | Temp. fluctuation: 3℃(at 260℃)JIS | Temp. rising time: Approx. 60min. | Interior /...
Tokio, JapónYamato SK601
- Fabricante: Yamato
Circulation method: Natural convection | Temp. setting range: Room temp. +5~260°C | Temp. control accuracy: ±1℃(at 260℃)JTM K05 | Temp. fluctuation: 3℃(at 260℃)JIS | Temp. rising time: Approx. 60min. | Interior /...
Tokio, JapónHORIBA, Ltd. XGT-9000SL
- Fabricante: Horiba
Xgt-9000sl pro: XGT-9000SL C | Instrument: X-ray analytical microscope with a super large chamber | Principle: Energy dispersive X-ray fluorescence spectroscopy | Available chamber size: 1030 mm (W) x 950 mm (D) ...
Kioto, JapónHORIBA Scientific Syncerity BI-NIR Camera
- Fabricante: Horiba
Back illuminated ccd technology: Enhanced near infrared sensitivity QE 42% at 1000 nm. | Deep thermoelectric cooling: –50°C @ +25°C ambient (–60°C @ +25°C ambient, on request) Yields low dark current suitable for...
Kioto, JapónYamato DKG610V
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30°C to 260°C | Temperature adjustment accuracy: ±0.5℃ | Temperature distribution accuracy: ±2℃(at 200℃)、±2.5℃(at 260℃) | Time to attain max. t...
Tokio, JapónHORIBA Advanced Techno Co., Ltd. HD-200
- Fabricante: Horiba
Product name: Dissolved oxygen converter | Combined sensor: 5505, 5510 (A bipolar diaphragm type polarography sensor) | Combined probe: DO-1100 | Saturation degree: 1% | Temperature: 0.1℃ | Linearity: Within ±0.0...
Kioto, JapónYamato SK801
- Fabricante: Yamato
Circulation method: Forced convection | Temp. setting range: Room temp. +10~210°C | Temp. control accuracy: ±1℃(at 210℃)JTM K05 | Temp. fluctuation: 2℃(at 210℃)JIS | Temp. rising time: Approx. 60min. | Interior /...
Tokio, JapónSMS Custom Spectroscopy Solutions
Excitation lasers: Discrete pulsed sources available from 260 nm to 1060 nm | Spectral range (cm-1) – free space: 80 – 9500 (532 nm), 80 – 6500 (633 nm), 80 – 3400 (785 nm) | Spectral range (cm-1) – fiber: 150 – ...
Kioto, JapónYamato RE601A-O
- Fabricante: Yamato
Motor: DC brushless motor (for rotation) | Controller: Vacuum regulator VR600 | Lift stroke: 130mm | Setting range of vacuum: 0 to 981hPa | Measurable range of vacuum: 0 to 1033hPa | Resolution of vacuum: 1hPa | ...
Tokio, JapónYamato SK811
- Fabricante: Yamato
Circulation method: Forced convection | Temp. setting range: Room temp. +10~210°C | Temp. control accuracy: ±1℃(at 210℃)JTM K05 | Temp. fluctuation: 2℃(at 210℃)JIS | Temp. rising time: Approx. 60min. | Interior /...
Tokio, JapónYamato DKG810
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30°C to 260°C | Temperature adjustment accuracy: ±0.5℃ | Temperature distribution accuracy: ±2℃(at 200℃)、±2.5℃(at 260℃) | Time to attain max. t...
Tokio, Japón