Building Filters

IT-27C
- Fabricante: Horiba
Measurement temperature range: -50 °C to 200 °C (Minimum unit 0.1°C) *1 | Spectral response: 8 μm to 14 μm *2 | Emissivity setting: 0.100 to 1.200 | Measurement accuracy: ±4.0°C (Target temperature: -50°C) ±0.8°C...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. TW-150
- Fabricante: Horiba
Product name: Water Distribution Monitor | Measurement items: (Standard configuration) turbidity, color, free residual chlorine, water pressure, pH (Optional items) conductivity, water temperature | Measurement m...
Kioto, Japón
LUX METER FT3424
Standards: DIN 5032-7: 1985 class B, JIS C 1609-1: 2006 general AA class | Light receiving element: Silicon photo diode | Range selection: Auto/ Manual | Linearity: ±2% rdg. (Multiply by 1.5 for display values i...
Nagano, Japón
MEMORY HiCORDER MR8880
- Fabricante: HIOKI E.E
Number of channels: 4 analog channels + 8 logic channels (standard) Note: Isolated analog channels, isolated input and frame, logic has common GND | Measurement ranges (10 div full-scale): 4 channels of voltage m...
Nagano, JapónYanmar HL1
- Fabricante: ヤンマー
- Modelo: HL1
- Potencia (hp): 5 CV
Caballos de fuerza: 4.7 hp | Tiempo de uso: — | Flete y método de envío: Por favor contáctenos | Situación de mantenimiento: Indecopado | Garantía de equipo usado: Ninguno
Kumagaya, Japón
PTFM-ONE-DT
- Fabricante: HORIBA UK Limited
900°c exhaust gas limit: Allows the freedom to test engines under extreme conditions without worrying if the flow meter can handle those temperatures | -1.25kpa to +7.5kpa sensor range: Shows both positive flow &...
Kioto, Japón
SS-120-W
Product name: Turbidity detector | Turbidity sensor type: SS-120-W Industrial-use turbidity detector | Formazin: 0 to 2000 (Display range: 0 to 2200 ) | Psl: 0 to 100 (degrees) (Display range: 0 to 110 (degrees))...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. SS-120-H
- Fabricante: Horiba
Product name: Turbidity detector | Turbidity sensor type: SS-120-H Turbidity detector | Formazin (ntu): 0 to 10.00 (NTU) (Display range: 0 to 11.00 (NTU)) | Psl: 0 to 10.00 (degrees) (Display range: 0 to 11.00 (d...
Kioto, Japón
HORIBA, Ltd. ENDA-5000
- Fabricante: Horiba
Repeatability: Within 0.5% of full scale/week (with optional range, or during O 2 measurement, ±1.0% of full scale/week) | Linearity (indicator error): ±1.0% of full scale | Zero drift: ±1.0% of full scale/week (...
Kioto, Japón
CLAMP ON EARTH TESTER FT6380-50
- Fabricante: HIOKI E.E
Measurement principle: Instrument has two cores for voltage injection and current measurement. From the defined voltage and measured current, the total circuit loop resistance is calculated Note: For multi groun...
Nagano, Japón
HORIBA Advanced Techno Co., Ltd. LO-300
- Fabricante: Horiba
Product name: Laser scanning type surface oil detector | Model number: LO-300 | Subject of detection: Oil on water surface or liquid on floor | Detection method: Surface scanning laser/reflected light sensor | De...
Kioto, Japón
MDLT-ONE
- Fabricante: HORIBA, Ltd.
Pm sampling method: Partial flow dilution method | Control modes for dilution: Proportional sampling mode (Const. split ratio)/ Fixed dilution ratio mode (Const. dilution ratio)/ Fixed flow rate mode (Manual cont...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. OPSA-150
- Fabricante: Horiba
Product name: Organic Pollutant Monitor (UV meter) | Measurement item: UV absorbance, VIS absorbance, COD conversion concentration, TURB (turbidity) conversion concentration | Measurement principle: Dual optical ...
Kioto, Japón
DPS-5600II
Interval type: Multi interval; Single inerval | Capacity: Max 3/6 kg; Max 6/15 kg; Max 15/30 kg; Max 30/60 lb; Max 30 lb | Scale interval: e=1/2 g; e=2/5 g; e=5/10 g; e=0.01/0.02 lb; e=0.01 lb | Weighing range: 2...
Tokio, Japón
EARTH TESTER FT6031-50
- Fabricante: HIOKI E.E
Measurement system: Two-electrode method/three-electrode method (switchable) | Measurement range: 20 Ω (0 Ω〜20.00 Ω) | Accuracy: ±1.5% rdg ±8 dgt | Earth voltage: 0〜30.0 V rms Accuracy: ±2.3% rdg ±8 dgt (50 Hz/60...
Nagano, Japón