Building Filters

TEST FIXTURE IM9202
Frequency range: DC to 600 MHz | Measurable dut: LEADED Axial • Distance between leads (component length): 1 mm to 25 mm (0.04 in. to 0.98 in.) • Lead length: 2 mm to 10 mm (0.08 in. to 0.39 in.) • Height to lead...
Nagano, Japón
HORIBA, Ltd. PG-300 series
- Fabricante: Horiba
Nox: 0-25/50/100/250/500/1000/2500 ppm | So2 ,co, ch4: Cross-Modulation Non-Dispersive Infrared Absorption Method | O2: 0-5/10/25 vol% (Zirconia Method, or Galvanic Method) 0-10/25 vol% (Paramagnetic Method (Dum...
Kioto, Japón
CHEMICAL IMPEDANCE ANALYZER IM3590
Measurement modes: LCR mode, Continuous measurement mode (LCR mode / Analyzer mode), Analyzer mode (Sweeps with measurement frequency and measurement level, temperature characteristics, equivalent circuit analysi...
Nagano, Japón
RESISTANCE METER RM3542A
Resistance range: [at Low Power OFF] 100 mΩ range (Max. 120.0000 mΩ, 0.1 μΩ resolution) to 100 MΩ range (Max. 120.0000 MΩ, 100 Ω resolution), 16 steps [at Low Power ON] 1000 mΩ range (Max. 1200.000 mΩ, 1 μΩ resol...
Nagano, Japón
LCR METER IM3536
Measurement modes: LCR (Measurement with single condition), Continuous testing (Continuous measurement under saved conditions) | Measurement parameters: Z, Y, θ, X, G, B, Q, Rdc (DC resistance), Rs (ESR), Rp, Ls,...
Nagano, Japón
AC CLAMP METER CM3289
Ac current range: 42.00 to 1000 A, 3 ranges (40 Hz to 1 kHz, True RMS), Basic accuracy: ±1.5 % rdg. ±5 dgt. | Dc voltage range: 420.0 mV to 600 V, 5 ranges, Basic accuracy: ±1.0 % rdg. ±3 dgt. | Ac voltage rang...
Nagano, Japón
C METER 3506-10
Measurement parameters: C (Capacitance), D (loss coefficient, tan δ), Q (1/tan δ) | Measurement range: C: 0.001 fF to 15.0000 μF, D: 0.00001 to 1.99999, Q: 0.0 to 19999.9 | Basic accuracy: (Typ.) C: ±0.14 % rdg.,...
Nagano, Japón
AUTOMATIC INSULATION / WITHSTANDING HiTESTER 3153
Functions: Program up to 32 files of 50 step test settings. 10 sets each of dielectric strength and insulation test settings, hold, buzzer | Monitor functions: Output voltage, detected current, measured resistanc...
Nagano, Japón
C HiTESTER 3504
Measurement parameters: C (capacitance), D (loss coefficient tan δ) | Measurement range: C: 0.9400 pF to 20.0000 mF, D: 0.00001 to 1.99999 | Basic accuracy: (Typ.) C: ±0.09 % rdg. ±10 dgt., D: ±0.0016 | Measur...
Nagano, Japón
EQUIVALENT CIRCUIT ANALYSIS FIRMWARE IM9000
Three-element model: Equivalent circuit model: Four models for Coil, Resistance, Capacitor Measurement items: L1 (Inductance), C1 (Capacitance), R1 (Resistance), Qm (Resonance sharpness), fr (Resonance frequency...
Nagano, Japón
HORIBA Scientific Nanolog
- Fabricante: Horiba
Excitation sources: Choice of: 450 W xenon short-arc lamp housing with off axis ellipsoidal collector and optional pulsed xenon lamp enhancement (for time resolved phosphorescence) 75 W xenon PowerArcTM lamp...
Kioto, Japón
HORIBA Scientific DeltaFlex
- Fabricante: Horiba
Function: Specification | Repetition rates: 10 kHz, 20 kHz, 50 kHz, 100 kHz, 250 kHz, 500 kHz, 1 MHz, 2 MHz, 4 MHz, 5 MHz, 8 MHz, 10 MHz, 16 MHz, 20 MHz, 25 MHz, 50 MHz, 80 MHz, 100 MHz, or Trigger Input (single-...
Kioto, Japón
AC CLAMP METER CM3291
Ac current range: 42.00 to 2000 A, 3 ranges (40 Hz to 1 kHz, True RMS), Basic accuracy 45-66 Hz: ±1.5% rdg. ±5 dgt. | Dc voltage range: 420.0 mV to 600 V, 5 ranges, Basic accuracy: ±1.0 % rdg. ±3 dgt. (at 4.2 V ...
Nagano, Japón
SUPER MEGOHM METER SM7120
Number of channels: 1 ch | Dc current measurement: 20 pA range (0.1 fA resolution), Accuracy: ±(2.0 % of rdg. +30 dgt.) 200 pA range (1.0 fA resolution), Accuracy: ±(1.0 % of rdg. +30 dgt.) 2 nA range (10 fA re...
Nagano, Japón
SUPER MEGOHM METER SM7110
Number of channels: 1 ch | Dc current measurement: 20 pA range (0.1 fA resolution), Accuracy: ±(2.0 % of rdg. +30 dgt.) 200 pA range (1.0 fA resolution), Accuracy: ±(1.0 % of rdg. +30 dgt.) 2 nA range (10 fA re...
Nagano, Japón