Yamato DKS200
- Fabricante: Yamato
Circulation type: Forced Convection | Operating temperature range: Room temp.+10 deg.C to 210 deg.C | Temp. control accuracy: ±1.0 deg.C (at 210 deg.C) | Temp. distribution accuracy: ±3.0 deg.C (at 210 deg.C) | M...
Tokio, Japón
HORIBA Advanced Techno Co., Ltd. HO-200
- Fabricante: Horiba
Product name: ORP meter | Combined sensor: ORP electrode | Temperature: 0.1℃ | Linearity: Within ±8 mA (output only) | Output type: Contact output with voltage (output of connected power supply voltage) | Load re...
Kioto, Japón
Yamato DKG810V
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30°C to 260°C | Temperature adjustment accuracy: ±0.5℃ | Temperature distribution accuracy: ±2℃(at 200℃)、±2.5℃(at 260℃) | Time to attain max. t...
Tokio, Japón
Yamato DKG610V
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30°C to 260°C | Temperature adjustment accuracy: ±0.5℃ | Temperature distribution accuracy: ±2℃(at 200℃)、±2.5℃(at 260℃) | Time to attain max. t...
Tokio, Japón
Yamato DKG810
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30°C to 260°C | Temperature adjustment accuracy: ±0.5℃ | Temperature distribution accuracy: ±2℃(at 200℃)、±2.5℃(at 260℃) | Time to attain max. t...
Tokio, Japón
Yamato DKG650V
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30°C to 260°C | Temperature adjustment accuracy: ±0.5℃ | Temperature distribution accuracy: ±2℃(at 200℃)、±2.5℃(at 260℃) | Time to attain max. t...
Tokio, Japón
Yamato DKG650
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30°C to 260°C | Temperature adjustment accuracy: ±0.5℃ | Temperature distribution accuracy: ±2℃(at 200℃)、±2.5℃(at 260℃) | Time to attain max. t...
Tokio, Japón
Yamato DXS200
- Fabricante: Yamato
Circulation type: Natural Convection | Operating temp.: Room Temp. +10 deg.C to 210 deg.C | Temp. adjustment accuracy: ±1 deg.C (at 210 deg.C) | Temp. fluctuation: 6 deg.C (at 210 deg.C) | Temp. distribution accu...
Tokio, Japón
Yamato DIR631
- Fabricante: Yamato
Method: IR radiation+Forced convection circulation and ventilation | Operating temperature range: Room temp. +10 to 360°C | Temp. fluctation: 2.0°C (at 360°C, when IR Heater is OFF) | Temp. gradient: 12°C (at 360...
Tokio, Japón
Yamato SI402
- Fabricante: Yamato
Circulation method: Natural convection (for laboratory use only) | Operating temp. range: Room temp. +5~260°C | Temp. adjustment accuracy: JTM K05 ±1°C (at 260°C) | Temp. distribution accuracy: JTM K05 ±6°C (at 2...
Tokio, Japón
Yamato SI601
- Fabricante: Yamato
Circulation method: Natural convection | Operating temp. range: Room temp. +5~260°C | Temp. adjustment accuracy: 2°C (at 260°C) | Temp. distribution accuracy: 20°C (at 260°C) | Max. temp. reaching time: Approx. 7...
Tokio, Japón
Yamato SI401
- Fabricante: Yamato
Circulation method: Natural convection | Operating temp. range: Room temp. +5~260°C | Temp. adjustment accuracy: 2°C (at 260°C) | Temp. distribution accuracy: 20°C (at 260°C) | Max. temp. reaching time: Approx. 7...
Tokio, Japón
Yamato CF820
- Fabricante: Yamato
Circulation type: Closed System Circulation By Pump | Operational ambient temperature: 5 deg.C to 35 deg.C | Operating temp. range: -20 deg.C to R.T. | Cooling capacity: Approx. 940W (810kcal/h) at Liquid temp. 1...
Tokio, Japón
MEMORY HiLOGGER LR8431
- Fabricante: HIOKI E.E
Number of channels: Analog: 10 isolated channels using scanning input method (M3 mm dia. screw terminal block) Pulse: 4 channels (All pulse inputs share common ground with the main unit) | Measurement parameters...
Nagano, Japón
HORIBA Advanced Techno Co., Ltd. HR-200
- Fabricante: Horiba
Measuring method: Polarography | Measuring range: Residual Chlorine: 0 mg/L to 3 mg/L Resolution: 0.01 mg/L Temperature: 0 to 50˚C Resolution: 0.1˚C | Repeatability: Residual Chlorine:Within ±0...
Kioto, Japón