Building Filters
Pekín, China
CNC Plasma
Max. cutting area: 1270mm * 1270mm (4' * 4'), 13000mm * 2540mm (4' * 8'), 1600mm * 3048mm (5' * 10'), 2032mm * 3048mm (6.7' * 10') | Z-axis move: 300mm (1'), 300mm (1'), 300mm (1'), 300mm (1') | Max. speed: 35m/m...
Tianjin, China
PLS-SXE300E/300EUV Xenon Light Source
- Fabricante: BEIJING PERFECTLIGHT TECHNOLOGY
Potencia de la lámpara: 300 W | Rango de ajuste de potencia: 150 W~300 W | Oscilación de potencia: 150 mV_p-p (valor pico a pico) | Tasa de ajuste de la carga de potencia: ±0.5% | Modo de visualización de corrien...
Pekín, China
CNC Waterjet
Rw1101: 500mm (20’’)(4'* 4'), 500mm(20’’)(4'* 8'), 150-200mm(6’’-7.9’’) | Rw1102: 1000mm(40’’), 1000mm(40’’), 150-200mm(6’’-7.9’’) | Rw1103: 1000mm(40’’), 1200mm(47’’), 150-200mm(6’’-7.9’’) | Rw1104: 1300mm(51’’)...
Tianjin, China
Combined low-pressure/vibration test chamber
- Fabricante: Angela Tongli Testing Technology
Pekín, China
Non-standard customized sunlight simulation test chamber
- Fabricante: Sunlight
Pekín, China
CEL-PAEM-D8PLUS photocatalytic activity evaluation system
- Fabricante: Beijing China Education Au-light
Pekín, China
Pekín, China
WMV660B three Channels ECG Machine
Plomo estandar: 7 derivaciones | Respuesta de frecuencia: 0,05~160 Hz(-3 dB) | Modo de trabajo: Hombre / Auto / Ritmo R-R | Nivel de ruido: <15μVp-p | Sensibilidad: 2.5, 5, 10, 20, 40, Auto (mm/mV) | Impedancia d...
Pekín, China
DM Tester-E Series Stability Test
- Fabricante: ACS
Pekín, China
Thermal Shock Chamber|Liquid to Liquid
- Fabricante: Angela Tongli Testing Technology
Pekín, China
CNC Plasma
Max. cutting area: 1300mm * 2500mm (4' * 8'), 1500mm * 3000mm (5' * 10'), 2000mm * 3000mm (6.7' * 10'), 2000mm * 4000mm (6.7' * 13') | Z-axis move: 300mm (1'), 300mm (1'), 300mm (1'), 300mm (1') | Max. speed: 35m...
Tianjin, China
WMV-670A Veterinary Portable X Ray System
Input power: Voltage: AC220V±22V Frequency: 50/60Hz±1Hz | Maximum output power: P =110kV×36mA=4kW | Nominal power: 100kV,40mA,0.1s,4kW | Kv adjusting range: 40kV~110kV,Continuous adjustment step 1 kV | Ma adjusti...
Pekín, China
Wondcon WMV-HD12-VET Top Veterinary Patient Monitor
Adjustable volume: 5 levels; | Measuring range: 20~300bpm | Measuring error: ± 0.1 C | Resolution: 1bpm | Accuracy: the bigger one between±2% or±2bpm | Standard configuration: universal adult ECG cable | Leads: 3...
Pekín, China
WMV650D Veterinary ETCO2 Monitor
Entrada de energía: 50Hz/60AC | Consumo de energía: 5W | Temperatura de trabajo: 5 -400C | Humedad: 30-75% (no condensación) | Presión atmosférica: 86-106kPa | Capacidad de la batería: 3,6V,1200mAh, aproximadamen...
Pekín, China
