Building Filters

Yamato CTA802
- Fabricante: Yamato
System: Integrated type, Air cooled electronic system, External open circulation | Operating temperature range: 0 to +70℃ | Temp. adjustment accuracy: ±0.1℃ | Cooling capacity: 163 kcal/h (189W) | Performance pum...
Tokio, Japón
Yamato CTW802S
- Fabricante: Yamato
System: Integrated type, Water cooled electronic system, External open circulation | Operating temperature range: -10oC to +70oC | Temp. adjustment accuracy: ±0.1℃ | Cooling capacity: 250 kcal/h (291W) | Performa...
Tokio, Japón
Yamato CTW402S
- Fabricante: Yamato
System: Separated type, Water cooled electronic system, External open circulation | Operating temperature range: -10oC to +70oC | Temp. adjustment accuracy: ±0.1℃ | Cooling capacity: 126 kcal/h (147W) | Performan...
Tokio, Japón
Yamato CTA812S
- Fabricante: Yamato
System: Separated type, Air cooled electronic system, External open circulation | Operating temperature range: 0 to +70℃ | Temp. adjustment accuracy: ±0.1℃ | Cooling capacity: 163 kcal/h (189W) | Performance pump...
Tokio, Japón
Yamato CTA812
- Fabricante: Yamato
System: Integrated type, Air cooled electronic system, External open circulation | Operating temperature range: 0 to +70℃ | Temp. adjustment accuracy: ±0.1℃ | Cooling capacity: 163 kcal/h (189W) | Performance pum...
Tokio, Japón
Yamato CTA802S
- Fabricante: Yamato
System: Separated type, Air cooled electronic system, External open circulation | Operating temperature range: 0 to +70℃ | Temp. adjustment accuracy: ±0.1℃ | Cooling capacity: 163 kcal/h (189W) | Performance pump...
Tokio, Japón
Yamato CTA412
- Fabricante: Yamato
System: Integrated type, Air cooled electronic system, External open circulation | Operating temperature range: 0 to +70℃ | Temp. adjustment accuracy: ±0.1℃ | Cooling capacity: 83 kcal/h (97W) | Performance pump ...
Tokio, Japón
Yamato CTA402
- Fabricante: Yamato
System: Integrated type, Air cooled electronic system, External open circulation | Operating temperature range: 0 to +70℃ | Temp. adjustment accuracy: ±0.1℃ | Cooling capacity: 83 kcal/h (97W) | Performance pump ...
Tokio, Japón
UV500 ATEX
Sample flow: Recommended : 0 - 5 L/MIN 0 – 0.5 l/min for NH4 or H2S | Sample pressure: 0 - 4 Bar (0 - 1 Bar with sampling peristaltic pump) 0 - 0.5 Bar for NH4 or H2S | Sample temperature: 0 °C to 80 °C 0 - 30 °C...
Kioto, Japón
Yamato CIW1100
- Fabricante: Yamato
Circulation method: External closed system circulation | Cooling method: Water-cooled type | Temperature control range: 0 - 80℃ (Operation of entire freezer) | Operating temperature range: 5 - 35℃ | Temp. adjustm...
Tokio, Japón
ALDAS-Mini : ELECTROLYSIS CELL ANALYZER
Measurement target: Electrolysis cell, cell stack | Measurement parameters: Impedance (R,X,θ,Z), voltage (V), current (I) | Measurement modes: Logging mode, Nyquist plot mode, Bode plot mode | Max. input ...
Nagano, Japón
RESISTANCE METER RM3545A
resistance range (13 ranges): [Range, Maximum display value, Resolutions, Testing current (Measurement current) ] 1000 μΩ: 1200.000 μΩ, 1 nΩ, 1 A 10 mΩ: 12.000 00 mΩ, 10 nΩ, 1 A 100 mΩ: 120.000 0 mΩ, 100 nΩ, 1 A...
Nagano, Japón
HORIBA Advanced Techno Co., Ltd. HE-200H
- Fabricante: Horiba
Product name: Conductivity meter | Sensors in combination: 4-electrode method conductivity sensor (FES Series) of cell constant 0.1/cm, or 1.0/cm | Display range: 0.0 to 220.0 | Temperature: 0.01℃ | Nacl: 0.0% to...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. HE-200C
- Fabricante: Horiba
Product name: Conductivity meter | Sensors in combination: 2-electrode method conductivity sensor ESH, ESD, ESL, and FS Series sensor of cell constant 0.01/cm,0.1/cm, or 1.0/cm | Temperature: 0.01℃ | Linearity: W...
Kioto, Japón
Yamato DP610
- Fabricante: Yamato
Method: Vacuum drying by decompressed chamber direct heating | Max. temp. reaching time: Approx. 100 min. | Interior material: Stainless steel | Exterior material: Cold rolled steel plate with baking coating | Do...
Tokio, Japón