Building Filters
Yamato BH501
- Fabricante: Yamato
Pump max. flow(50/60hz): 14/15L/min. (Circulation pressure loss when below 10kPa) | Pump max. lift(50/60hz): 2.8/3.4m (water flow about 0.5L/min) | Circulation system: Water jet pump circulation /External closed ...
Tokio, JapónYamato FP102
- Fabricante: Yamato
Operating temp. range: 100~1,150℃ | Temp. control accuracy: ±1.0℃(at 1150℃) | Temp. fluctuation: 2.0℃(at 1150℃) | Temp. distribution: ±4.0℃(at 1150℃) | Temp. gradient: 14℃(at 1150℃) | Max. temp. reaching time: Ap...
Tokio, JapónYamato DKG811V
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30°C to 260°C | Temperature adjustment accuracy: ±0.5℃ | Temperature distribution accuracy: ±2℃(at 200℃)、±2.5℃(at 260℃) | Time to attain max. t...
Tokio, JapónYamato SQ810C Limited product for overseas
- Fabricante: Yamato
System: Automatic high-pressure steam sterilization | Operating temperature range: 45~135℃(45~80℃[pre heating temperature]/45~60℃[heat retention phase ]/65~100℃[disolution phase ]/105~135℃[sterilizing phase]) | M...
Tokio, JapónYamato SM520 Limited product for overseas
- Fabricante: Yamato
System: Automatic high-pressure steam sterilization | Operating temp. range (sterilization): 105~135℃ | Operating temp. range (drying): 135~150℃ | Max. pressure capacity: 0.255MPa | Operable ambient temp.: 5~35℃ ...
Tokio, JapónYamato SM530 Limited product for overseas
- Fabricante: Yamato
System: Automatic high-pressure steam sterilization | Operating temp. range (sterilization): 105~135℃ | Operating temp. range (drying): 135~150℃ | Max. pressure capacity: 0.255MPa | Operable ambient temp.: 5~35℃ ...
Tokio, JapónYamato SM820 Limited product for overseas
- Fabricante: Yamato
System: Automatic high-pressure steam sterilization | Operating temp. range (sterilization): 105~135℃ | Operating temp. range (drying): 135~150℃ | Max. pressure capacity: 0.255MPa | Operable ambient temp.: 5~35℃ ...
Tokio, JapónYamato SM830 Limited product for overseas
- Fabricante: Yamato
System: Automatic high-pressure steam sterilization | Operating temp. range (sterilization): 105~135℃ | Operating temp. range (drying): 135~150℃ | Max. pressure capacity: 0.255MPa | Operable ambient temp.: 5~35℃ ...
Tokio, JapónYamato BV100
- Fabricante: Yamato
Stirring system: Peltiert device with heater, Stirring by pump | Operating temp. range: 0 to 80°C (periphery temperature 20°C) | Temp. adjustment accuracy: ±0.1°C (Water temp. 20°C, Room temp. 20°C) | Temp. distr...
Tokio, JapónYamato DF412
- Fabricante: Yamato
System: Forced convection and ventilation | Operating temp. range: Room temp. + 15 to 260℃ | Temp. control accuracy (jtm k05): ±0.1℃(at 260℃) | Temp. fluctuation (jis): 1.0℃(at 260℃) | Temp. distribution accuracy...
Tokio, JapónYamato DH612
- Fabricante: Yamato
System: Forced convection and ventilation | Operating temp. range: Room temp. + 15 to 360℃ | Temp. control accuracy (jtm k05): ±0.2℃(at 360℃) | Temp. fluctuation (jis): 2.0℃(at 360℃) | Temp. distribution accuracy...
Tokio, JapónYamato DH412
- Fabricante: Yamato
System: Forced convection and ventilation | Operating temp. range: Room temp. + 15 to 360℃ | Temp. control accuracy (jtm k05): ±0.2℃(at 360℃) | Temp. fluctuation (jis): 2.0℃(at 360℃) | Temp. distribution accuracy...
Tokio, JapónYamato DF612
- Fabricante: Yamato
System: Forced convection and ventilation | Operating temp. range: Room temp. + 15 to 260℃ | Temp. control accuracy (jtm k05): ±0.1℃(at 260℃) | Temp. fluctuation (jis): 1.0℃(at 260℃) | Temp. distribution accuracy...
Tokio, JapónYamato CA801
- Fabricante: Yamato
Method: Direct trap or Glass trap (optional) | Dehumidifying capacity: Max. 1.0kg(Water type liquid) | Max. low temperature: -85℃ | Refrigerator: Air cooling, 350W | Refrigerant: R600a and other mixed coolant | C...
Tokio, JapónYamato BNA600
- Fabricante: Yamato
System: Water jacket | Operating temp. range: (Room Temp.+5℃)~50℃ | Temp. control accuracy: ±0.1℃(at 37℃) | Temp. distribution accuracy: ±0.2℃(at37℃) | Humidity in operation: More than 95%RH | Co2 concentration r...
Tokio, Japón