Building Filters

DIGITAL MULTIMETER DT4282
Dc voltage range: 60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt. | Ac voltage(*1) range: 60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHz Basic accuracy 45 - 65 ...
Nagano, Japón
DIGITAL MULTIMETER DT4261
Dc voltage range: 600.0 mV to 1000 V, 5 ranges, Basic accuracy: ±0.15% rdg. ±2 dgt. | Ac voltage range: 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz Basic accuracy 40 Hz - 500 Hz: ±0.9% ...
Nagano, Japón
DIGITAL MULTIMETER DT4255
Dc voltage range: 600.0 mV to 1000 V 5 ranges, Basic accuracy: ±0.3 % rdg. ±3 dgt. | Ac voltage range: 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz Basic accuracy 40 - 500 Hz : ±0.9 % rd...
Nagano, Japón
DIGITAL MULTIMETER DT4252
Dc voltage range: 600.0 mV to 1000 V, 5 ranges Basic accuracy: ±0.3 % rdg. ±5 dgt. | Ac voltage range: 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz - 1 kHz Basic accuracy 40 - 500 Hz : ±0.9 % rdg...
Nagano, Japón
DIGITAL MULTIMETER DT4253
Dc voltage range: 600.0 mV to 1000 V 5 ranges, Basic accuracy: ±0.3 % rdg. ±5 dgt. | Ac voltage range: 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz Basic accuracy 40 - 500 Hz : ±0.9 % rd...
Nagano, Japón
DIGITAL MULTIMETER DT4256
Dc voltage range: 600.0 mV to 1000 V, 5 ranges Basic accuracy: ±0.3 % rdg. ±3 dgt. | Ac voltage range: 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz Basic accuracy 40 - 500 Hz : ±0.9 % rd...
Nagano, Japón
AC CLAMP METER CM3281
Ac current range: 42.00 to 2000 A, 3 ranges (50 Hz to 60 Hz, Average rectified), Basic accuracy 50-60 Hz: ±1.5% rdg. ±5 dgt. | Dc voltage range: 420.0 mV to 600 V, 5 ranges, Basic accuracy: ±1.0 % rdg. ±3 dgt. (...
Nagano, Japón
AC CLAMP METER CM3291
Ac current range: 42.00 to 2000 A, 3 ranges (40 Hz to 1 kHz, True RMS), Basic accuracy 45-66 Hz: ±1.5% rdg. ±5 dgt. | Dc voltage range: 420.0 mV to 600 V, 5 ranges, Basic accuracy: ±1.0 % rdg. ±3 dgt. (at 4.2 V ...
Nagano, Japón
HORIBA Scientific VU90 Spectrometer
- Fabricante: Horiba
Spectral coverage: 115 - 230 nm Full coverage on CCD: 115 - 320 nm (No order sorting filter available) | Spectral resolution: 0.5 nm with 22 μm pinhole, 0.75 nm with 40 μm pinhole | Spectral dipersion: 12 nm/mm; ...
Kioto, Japón
SENSOR DE TOPE ACTIVO 9272-05
Corriente nominal: 20 A AC, o 200 A AC (seleccionable) | Entrada máxima permitida: 50 A rms (en rango de 20 A), 300 A rms (en rango de 200 A) | Características de frecuencia: 1 Hz (±2 % rdg. ±0.1 % f.s.) a 100 kH...
Nagano, Japón
AC/DC CLAMP METER CM4373-50
Dc current range: 600.0 A/2000 A, Basic accuracy: ±1.3% rdg. ±0.3 A (600 A range) | Ac current range: 600.0 A/2000 A (10 Hz to 1 kHz, True RMS), Basic accuracy 45 - 66 Hz: ±1.3% rdg. ±0.3 A (at 600 A) | Crest fac...
Nagano, Japón
AC/DC CLAMP METER CM4371-50
Dc current range: 20.00 A/600.0 A, Basic accuracy: ±1.3% rdg. ±0.08 A (20 A range) | Ac current range: 20.00 A/600.0 A (10 Hz to 1 kHz, True RMS), Basic accuracy: 45-66 Hz: ±1.3% rdg. ±0.08 A (at 20 A) | Crest fa...
Nagano, Japón
GX-100
Product name: Modular Water Supply Quality Monitor | Measurement items: Turbidity, color, free residual chlorine, water pressure, pH, conductivity, water temperature (Flow rate can also be selected and displayed ...
Kioto, Japón
AC/DC CLAMP METER CM4375-50
Dc current range: 1000 A, (Max. display 999.9 A) , Basic accuracy: ±1.3% rdg. ±0.3 A (at 30.1 A - 999.9 A) | Ac current range: 1000 A (Max. display 999.9 A, 10 Hz to 1 kHz, True RMS), Basic accuracy 45-66 Hz: ±1...
Nagano, Japón
AC CLAMP METER CM4141-50
Ac current range: 60.00 A to 2000 A, 3 ranges (45 Hz to 1 kHz, True RMS), Basic accuracy 45-66 Hz: ±1.5% rdg. ±0.08 A (60 A range) | Crest factor: For the 60.00 A range: 2.5 (greater than 50.00 A and less than or...
Nagano, Japón