Building Filters

HK-368 Inductive Concentration/Conductivity Analyzer
Material code: HK-368 | Manufacturers.: hky technology co.,ltd. | ◆ communication: RS485/PROFIBUS-DP/HART, choose one. | Transmitter: 1 set | Sensor: 1 set | Installation component: 1 set (choose one) | Display.:...
Pekín, ChinaRelé de retardo ABB SACE YU DELAY 702209/80-5
- Fabricante: ABB
Ajmán, Emiratos Árabes Unidos
HORIBA Advanced Techno Co., Ltd. NO-2000
- Fabricante: Horiba
Product name: Ammonia/Nitrate Nitrogen Meter | Converter model: HC-200N | Sensor model: NO-2000: Nitrate nitrogen sensor | Sensor tip model: 7693: Nitrate ion tip, 7694: Chloride ion tip for compensation, 7211: R...
Kioto, Japón
Yamato ILE800
- Fabricante: Yamato
Circulation method: Natural convection by air jacket | Operating temperature range: 0 to +60℃ | Temp. control accuracy: ±0.2℃ (when refrigerator is in the continuous operation) ±0.3℃ (when refrigerator is in the ...
Tokio, Japón
HORIBA Advanced Techno Co., Ltd. HP-200-K (Four-Wire Analyzer)
- Fabricante: Horiba
Measuring method: Glass electrode method | Measuring range: pH: 0 to 14 pH Resolution: 0.01 pH Temperature: 0 to 100˚C Resolution: 0.1˚C | Repeatability: pH: ±0.03 or less Temperatu...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. HP-960FTP
- Fabricante: Horiba
Product name: Industrial pH meter | Measuring range: 0 pH to 14 pH: 0.01 pH resolution. Temperature 0℃ to 100℃: 1℃ resolution (selectable display). | Repeatability: Within±0.05 pH (Equivalent input) | Linearity: ...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. HP-480TP
- Fabricante: Horiba
Product name: Industrial pH meter | Measuring range: 0 pH to 14 pH: 0.01 pH resolution. Temperature 0℃ to 100℃: 1℃ resolution (selectable display). | Transmission output: 4 mA to 20 mA DC, input/output isolated t...
Kioto, Japón
HORIBA, Ltd. APMA-380
- Fabricante: Horiba
Component: Carbon monoxide (CO) | Measuring principle: Cross-Modulation Non-Dispersive Infrared Absorption (NDIR) | Measurement range: 0-5/10/20/50/100/300 ppm (up to 6 ranges selectable, auto-range) | Lower dete...
Kioto, Japón
Yamato BB401
- Fabricante: Yamato
Operating temperature range: -30 to +80°C | Temperature control accuracy: ±0.1°C | Temperature distribution accuracy: ±0.3°C | Temperature indicating unit: 0.1°C | Cooling capacity: Approx. 475W (408Kcal/h), at f...
Tokio, Japón
Yamato BB301
- Fabricante: Yamato
Operating temperature range: -30 to +80°C | Temperature control accuracy: ±0.1°C | Temperature distribution accuracy: ±0.3°C | Temperature indicating unit: 0.1°C | Cooling capacity: Approx. 420W (361Kcal/h), at f...
Tokio, Japón
Yamato BH302
- Fabricante: Yamato
Circulation type: Water Jet Pump Circulation (Closed System Circulation) | Operating temp. range: -20deg.C to 80deg.C | Temp. adjustment accuracy: ±0.02deg.C JTM K05 (at 20 deg.C) ±0.05deg.C JIS ( at 20 deg.C) | ...
Tokio, Japón
HORIBA Advanced Techno Co., Ltd. HD-480
- Fabricante: Horiba
Product name: Dissolved oxygen meter | Measurement method: Galvanic cell method | Measuring range: Dissolved oxygen 0 mg/L to 20 mg/L, 0.01 mg/L resolution Saturation 0% to 200%, 1% resolution Temperature 0℃ to 4...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. HR-480
- Fabricante: Horiba
Product name: Industrial Residual Chlorine Meter | Measurement method: Galvanic cell method | Repeatability: Within ±0.05 mg/L (with equivalent input) | Linearity: Within ±0.05 mg/L (with equivalent input) | Tran...
Kioto, Japón
Yamato DT611
- Fabricante: Yamato
Temp. distribution accuracy: ±4.0°C (at 360°C) JTM K05 | Max. temp. reaching time: Approx. 80 min. (at 360°C) | Heater: Stainless pipe heater | Cable hole: 33mm I.D. ×1 | Timer: 1 min. to 99 Hrs. 59 min | Operati...
Tokio, Japón
AC/DC CURRENT PROBE CT6833, CT6833-01
Rated current: 200 A AC/DC | Frequency bandwidth: DC to 50 kHz | Diameter of measurable conductor: Max. φ20 mm (0.79 in.) | Maximum peak current: Up to ±600 A peak are permitted at a temperature of 40°C (104°F) o...
Nagano, Japón
