IMPEDANCE ANALYZER IM7581
Measurement modes: LCR mode, Analyzer mode (Sweeps with measurement frequency and measurement level), Continuous measurement mode | Measurement parameters: Z, Y, θ, Rs (ESR), Rp, X, G, B, Cs, Cp, Ls, Lp, D (tanδ...
Nagano, Japón
DIFFERENTIAL PROBE P9000
- Fabricante: HIOKI E.E
Measurement functions: Waveform monitor output only Frequency characteristics: DC to 100 kHz, -3 dB | Division ratio: 1000:1 or 100:1 (user selectable) | Dc amplitude accuracy: ±0.5% f.s. (f.s. = 1.0 V; voltage d...
Nagano, Japón
IMPEDANCE ANALYZER IM7585
Measurement modes: LCR mode, Analyzer mode (sweeps with measurement frequency and measurement level), Continuous measurement mode | Measurement parameters: Z, Y, θ, Rs (ESR), Rp, X, G, B, Cs, Cp, Ls, Lp, D (tanδ...
Nagano, Japón
IMPEDANCE ANALYZER IM7583
Measurement modes: LCR mode, Analyzer mode (Sweeps with measurement frequency and measurement level), Continuous measurement mode | Measurement parameters: Z, Y, θ, Rs (ESR), Rp, X, G, B, Cs, Cp, Ls, Lp, D (tanδ...
Nagano, Japón
RESISTANCE METER RM3545A
resistance range (13 ranges): [Range, Maximum display value, Resolutions, Testing current (Measurement current) ] 1000 μΩ: 1200.000 μΩ, 1 nΩ, 1 A 10 mΩ: 12.000 00 mΩ, 10 nΩ, 1 A 100 mΩ: 120.000 0 mΩ, 100 nΩ, 1 A...
Nagano, Japón
Yamato WG1012
- Fabricante: Yamato
Water purifying method: Ion exchange→Distillation→Filtration | Sampled pure water method: Ion-exchanged water / distilled water | Distilled water production: Approximately 5L / h | Amount of distilled water colle...
Tokio, Japón
UV500 ATEX
Sample flow: Recommended : 0 - 5 L/MIN 0 – 0.5 l/min for NH4 or H2S | Sample pressure: 0 - 4 Bar (0 - 1 Bar with sampling peristaltic pump) 0 - 0.5 Bar for NH4 or H2S | Sample temperature: 0 °C to 80 °C 0 - 30 °C...
Kioto, Japón
Yanase snow plower 88F2 III 88F junk 2 unit set! Parts can be taken out
- Fabricante: Yanase
Tsuruoka, Japón
HORIBA Advanced Techno Co., Ltd. LO-300
- Fabricante: Horiba
Product name: Laser scanning type surface oil detector | Model number: LO-300 | Subject of detection: Oil on water surface or liquid on floor | Detection method: Surface scanning laser/reflected light sensor | De...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. 5700A
- Fabricante: Horiba
Measuring method: Optical (fluorescent) | Measuring range: DO: 0 to 20 mg/L Resolution: 0.01 mg/L Saturation: 0 to 200% Resolution: 0.1% Temperature: 0 to 50°C Resolution: 0.1°C | Transmission output: 2...
Kioto, Japón
HORIBA, Ltd. VA-5000 / VA-5000WM Series
- Fabricante: Horiba
Communication: Ethernet (ModbusTM/TCP) | Output: Maximum 16ch isolated, Maximum voltage DC 30 V, Maximum current 1A Minimum voltage DC 0.1 V, Minimum current 0.1 mA | Sample condition: Ambient temperature, dust f...
Kioto, Japón
MEMORY HiLOGGER LR8431
- Fabricante: HIOKI E.E
Number of channels: Analog: 10 isolated channels using scanning input method (M3 mm dia. screw terminal block) Pulse: 4 channels (All pulse inputs share common ground with the main unit) | Measurement parameters...
Nagano, Japón
HORIBA, Ltd. TX-100
- Fabricante: Horiba
Name: Tunable Laser Gas Analyzer | Measurement target: HCl and H 2 O in process gas | Measurement component: HCl, H 2 O | Measurement principle: Non Dispersive Infrared (NDIR) | Measurement type: Probe type ...
Kioto, Japón
HORIBA, Ltd. ENDA-5000
- Fabricante: Horiba
Repeatability: Within 0.5% of full scale/week (with optional range, or during O 2 measurement, ±1.0% of full scale/week) | Linearity (indicator error): ±1.0% of full scale | Zero drift: ±1.0% of full scale/week (...
Kioto, Japón
PTFM-ONE-DT
- Fabricante: HORIBA UK Limited
900°c exhaust gas limit: Allows the freedom to test engines under extreme conditions without worrying if the flow meter can handle those temperatures | -1.25kpa to +7.5kpa sensor range: Shows both positive flow &...
Kioto, Japón