Building Filters
S150 Large Jaw Cable Fault Location Supermalloy Current Transformer Clamp
Ratio: 10001, 2005 or... 30005 (customized) | Accuracy class: 0.1%, 0.2%, 0.5% | Primary current: 0-3000A AC | Secondary current: 0-1A or 0-5A AC (customized) | Secondary voltage: 0-1V, 0-5V AC (customized) | Max...
Pekín, ChinaGF106FY Current transformer & voltage transformer burden box
Accuracy class: 3 | Rated current: 5A, 1A | Power factor and rated capacity iec60044-1/iec61869-2: COSФ=0.8: 2.5/3.75/5/6.25/7.5/10/12.5/15/20/30/40/50/60VA COSФ=1.0: 2.5/3.75/5/6.25/7.5/10VA | Power factor and r...
Pekín, ChinaGf1060M Miniature Current Transformer Test Equipment
Accuracy class: Ratio error | Power supply: Single phase AC 220V±10% or 110V±10% , frequency 50/60Hz | Range: 0.2A, 1A, 5A | Adjustment range: (0-120)%RG | Adjust fineness: 0.01%RG | Accuracy: 0.05% RD | Stabilit...
Pekín, ChinaT-213S Three Phase Transformer Dc Resistance Test Equipment
Power supply: Single phase AC 220V±10% or 110V±10% , 50/60HzAC | Cooling way: Intermittent air cooled | Single channel current output: 1A, 5A, 10A, 20A | Three channel current output: 1A+1A, 5A+5A, 10A+10A | Test...
Pekín, ChinaT-218 Automatic Portable Transformer Demagnetization Tester
Suministro de energía: AC monofásico 220V±10% o 110V±10%, 50/60Hz AC | Forma de refrigeración: Enfriado por aire intermitente | Salida de corriente: 200 mA, 1 A, 5 A (10 A, 20 A, 50 A opcional) | Lcd: Pantalla TF...
Pekín, China- Pekín, China
TEST-200 200A portable primary current injection test kit
Accuracy: <0.2% | Power supply(ac): 220V±10% 2000VA, 50Hz/60Hz or 110V±10% 2000VA, 50Hz/60Hz | Current output (ac): 200A·5V or 100A·10V | Capacity: 2KVA | The current output waveform distortion: ≤5% | Dual protec...
Pekín, ChinaTEST-901 large current 1000a primary current injection test set
Accuracy: <0.2% ±2words | Power supply (ac): 220V±10% 25A, 50Hz/60Hz or 110V±10% 50A, 50Hz/60Hz | Current output (ac): 1000A·5V or 500A·10V | Capacity: 5KVA | The current output waveform distortion: ≤5% | Dual pr...
Pekín, China- Pekín, China
GF106T portable ct pt analyzer
Accuracy: ≤0.2% | Power supply: AC 220V±10% or AC 110V±10% , 50/60Hz | Excitation voltage output: 0-2500Vrms | Excitation current output: 0-5Arms (20A peak-value) | Large current output: 0-1000A | Large current c...
Pekín, China- Pekín, China
GF1061CT Portable ct analyzer with printer
Accuracy: ≤0.02% or 0.05% | Power supply: Single phase AC 85-265V, 50/60Hz or battery | Output current: 0-5Arms (20A peak-value) | Output power: 0-400VA (1500 VApeak) | Automatic frequency variation range: 0.1-60...
Pekín, ChinaGF1061PT portable voltage transformer tester
Accuracy: ≤0.05% | Power supply: AC 220V±10% or AC 120V±10% , 50/60Hz or battery | Output voltage: 0-100Vrms | Output current: 0-5Arms (20A peak-value) | Output power: 0-400VA (1500 VApeak) | Automatic frequency ...
Pekín, China- Pekín, China
GFLZZ0954-10E presicion ANSI 5A CTs current transformer supplier
Normas: IEC60044; IEC 61869; ANSI/IEEE C57.13 | Corriente primaria nominal: 5-1250A | Carga nominal: ≤15 VA | Frecuencia nominal: 50 Hz o 60 Hz | Corriente secundaria nominal: 5 A o 1 A | Corriente térmica nomina...
Pekín, China