Building Filters
- Vendedor de confianza

MKS Micro Vision2 Gas Analyzer Assembly Pfeiffer SplitFlow80 Vacuum AS-IS
- Fabricante: MKS
Model no.: PM P04 013 | Connection flanges, in and out: G 1/8" | Inlet pressure max.: 1500 hPa (absolute) | Gas flow at atmospheric pressure: 130 hPa·l/s | Leakage rate: < 1 · 10-9 Pa m3/s, < 7.5 · 10-9 Torr l/s,...
$3,995 USDBelgium, Wisconsin - Vendedor de confianza
Entegris 6500-T2-F02-H04-M-P2-U1 InVue Integrated Flow Controller Working Spare
- Fabricante: Entegris
Mpn: 6500-T2-F02-H04-M-P2-U1 | Número de pieza: 6500-T2-F02-H04-M-P2-U1
$705 USDAlbuquerque, Nuevo México 
SONIMIX 7100
- Fabricante: LNI Swissgas
Models sonimix 7100: Sx 7100 2L1R Sx 7100 2L2RSx 7100 2L3RSx 7100 Multi Gas | Dilution range: 10 – 100 %1 – 100 %0,1 – 100 %– | Dilution principle: Mass Flow Controllers | Dilution gas line flow accuracy: 0.5 % (...
Milán, Italia
SONIMIX 2130
- Fabricante: LNI Swissgas
Models sx 2130: 6800 50 0016800 50 0026800 50 003 | Concentration: LowHigh | No2 & o3 generation: 15 to 50 ppm30 to 100 ppm300 to 1000 ppm | Inlet pressure: 2,5 to 4 bar rel.(37 to 58 PSI) | Outlet pressure: Up t...
Milán, Italia
HORIBA Europe GmbH APMC-370
- Fabricante: Horiba
Principle of test gas production: via dilution | Accuracy: 0,1°C | Optional o3 generation: Internal O 3 via a UV tube in a thermostatically controlled enclosure Maximum concentration ±500ppb at 1l/min | Temperatu...
Kioto, Japón
SONIMIX 7050
- Fabricante: LNI Swissgas
Model sx 7050: SX 7050 2L1RSX 7050 2L2RSX 7050 2L3R | Flow rate (max): 3,5 or 5 L /min (other flow under request) | Dilution: MFC (mass Flow Controllers) | Dilution range: 10% to 100%1% to 100%0.1% to 100% | Carr...
Milán, Italia
TCA-5000
Measurement principle: Thermal conductivity detection method | Measurement range: (Min.) 0 - 10 vol% (Max.) 0 - 100 vol% | Measurement range (optional): 0 - 5 vol% to less than 10 vol% 100 - 90 vol...
Kioto, Japón
MEXA-ONE-QL-NX
- Fabricante: HORIBA, Ltd.
Measuring principle: Quantum Cascade Laser Infrared (QCL-IR) Spectroscopy | Measuring components: NO・NO 2 ・N 2 O・NH 3 | Measuring range: NO: (low) 0-100 ppm (high) 0-5000 ppm NO 2 :(low) 0- 50 ppm (h...
Kioto, Japón
HORIBA, Ltd. PG-300 series
- Fabricante: Horiba
Nox: 0-25/50/100/250/500/1000/2500 ppm | So2 ,co, ch4: Cross-Modulation Non-Dispersive Infrared Absorption Method | O2: 0-5/10/25 vol% (Zirconia Method, or Galvanic Method) 0-10/25 vol% (Paramagnetic Method (Dum...
Kioto, Japón
HORIBA, Ltd. 51 series
- Fabricante: Horiba
Measuring principle: Non-Dispersive Infrared Absorption Method (NDIR) | Component: CO, CO 2 , CH 4 , etc. *1 | Span ±0.5% of full scale: Span : ±1.0% of full scale | Linearity: ±1.0% of full scale | Optional ran...
Kioto, Japón
HORIBA, Ltd. TX-100
- Fabricante: Horiba
Name: Tunable Laser Gas Analyzer | Measurement target: HCl and H 2 O in process gas | Measurement component: HCl, H 2 O | Measurement principle: Non Dispersive Infrared (NDIR) | Measurement type: Probe type ...
Kioto, Japón
PS-300S
- Fabricante: Horiba
Measurement principle: NDIR: Non-Dispersive Infrared | Linearity: ±2% full scale | Zero drift: ±2% full scale per day | Span drift: ±2% full scale per day | Sample gas flow rate: Max. 0.5 L/min | Display: 5.7-inc...
Kioto, Japón
HORIBA, Ltd. ENDA-5000
- Fabricante: Horiba
Repeatability: Within 0.5% of full scale/week (with optional range, or during O 2 measurement, ±1.0% of full scale/week) | Linearity (indicator error): ±1.0% of full scale | Zero drift: ±1.0% of full scale/week (...
Kioto, Japón
PLGA-1000
Name: Process Laser Gas Analyzer | Measurement principle: NDIR: Non Dispersive Infrared | Light source: QCL: Quantum Cascade Laser | Laser class: Class 1(IEC 60825-1:2014) | Components*¹: Methane (CH 4 ), Ethane ...
Kioto, Japón
HORIBA, Ltd. VA-5000 / VA-5000WM Series
- Fabricante: Horiba
Communication: Ethernet (ModbusTM/TCP) | Output: Maximum 16ch isolated, Maximum voltage DC 30 V, Maximum current 1A Minimum voltage DC 0.1 V, Minimum current 0.1 mA | Sample condition: Ambient temperature, dust f...
Kioto, Japón