Building Filters
- Vendedor de confianza

MKS Micro Vision2 Gas Analyzer Assembly Pfeiffer SplitFlow80 Vacuum AS-IS
- Fabricante: MKS
Model no.: PM P04 013 | Connection flanges, in and out: G 1/8" | Inlet pressure max.: 1500 hPa (absolute) | Gas flow at atmospheric pressure: 130 hPa·l/s | Leakage rate: < 1 · 10-9 Pa m3/s, < 7.5 · 10-9 Torr l/s,...
$3,995 USDBelgium, Wisconsin 
TCA-5000
Measurement principle: Thermal conductivity detection method | Measurement range: (Min.) 0 - 10 vol% (Max.) 0 - 100 vol% | Measurement range (optional): 0 - 5 vol% to less than 10 vol% 100 - 90 vol...
Kioto, Japón
HORIBA, Ltd. GI-700
- Fabricante: Horiba
Indicated error (linearity): ± 1.0 % of full-scale value for each component and range (Standard range ratio) ± 2.0 % of full-scale value for each component and range (Optinonal range ratio) | Zero drift: ± 1.0%/w...
Kioto, Japón
HORIBA, Ltd. VA-5000 / VA-5000WM Series
- Fabricante: Horiba
Communication: Ethernet (ModbusTM/TCP) | Output: Maximum 16ch isolated, Maximum voltage DC 30 V, Maximum current 1A Minimum voltage DC 0.1 V, Minimum current 0.1 mA | Sample condition: Ambient temperature, dust f...
Kioto, Japón
MEXA-ONE-QL-NX
- Fabricante: HORIBA, Ltd.
Measuring principle: Quantum Cascade Laser Infrared (QCL-IR) Spectroscopy | Measuring components: NO・NO 2 ・N 2 O・NH 3 | Measuring range: NO: (low) 0-100 ppm (high) 0-5000 ppm NO 2 :(low) 0- 50 ppm (h...
Kioto, Japón
HORIBA, Ltd. APOA-380
- Fabricante: Horiba
Component: Ozone (O 3 ) | Measuring principle: Cross-Modulation Non-Dispersive Ultraviolet Absorption (NDUV) | Measurement range: 0 - 0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 5.0 / 10 ppm *1 (up to 7 ranges selectable,...
Kioto, Japón
HORIBA, Ltd. APMA-380
- Fabricante: Horiba
Component: Carbon monoxide (CO) | Measuring principle: Cross-Modulation Non-Dispersive Infrared Absorption (NDIR) | Measurement range: 0-5/10/20/50/100/300 ppm (up to 6 ranges selectable, auto-range) | Lower dete...
Kioto, Japón
HORIBA, Ltd. APNA-380
- Fabricante: Horiba
Component: Nitrogen oxides (NO, NO 2 , NOx) | Measuring principle: Cross-Modulation Chemiluminescence | Measurement range: 0-0.1/0.2/0.5/1.0/2.0/5.0/10/20 ppm (up to 8 ranges selectable, auto-range) | Lower detec...
Kioto, Japón
HORIBA, Ltd. PG-300 series
- Fabricante: Horiba
Nox: 0-25/50/100/250/500/1000/2500 ppm | So2 ,co, ch4: Cross-Modulation Non-Dispersive Infrared Absorption Method | O2: 0-5/10/25 vol% (Zirconia Method, or Galvanic Method) 0-10/25 vol% (Paramagnetic Method (Dum...
Kioto, Japón
PS-300S
- Fabricante: Horiba
Measurement principle: NDIR: Non-Dispersive Infrared | Linearity: ±2% full scale | Zero drift: ±2% full scale per day | Span drift: ±2% full scale per day | Sample gas flow rate: Max. 0.5 L/min | Display: 5.7-inc...
Kioto, Japón
HORIBA, Ltd. TX-100
- Fabricante: Horiba
Name: Tunable Laser Gas Analyzer | Measurement target: HCl and H 2 O in process gas | Measurement component: HCl, H 2 O | Measurement principle: Non Dispersive Infrared (NDIR) | Measurement type: Probe type ...
Kioto, Japón
MEXA-1300R
- Fabricante: HORIBA, Ltd.
Compatible standards: CE, FCC (Class A) | Analyzing target: Exhaust gases of two-cycle and four-cycle engines | Measurement item and range: CO : 0.00% vol - 10.00% vol HC : 0ppm vol - 10,000ppm vol (N-hexane) CO...
Kioto, Japón
PLGA-1000
Name: Process Laser Gas Analyzer | Measurement principle: NDIR: Non Dispersive Infrared | Light source: QCL: Quantum Cascade Laser | Laser class: Class 1(IEC 60825-1:2014) | Components*¹: Methane (CH 4 ), Ethane ...
Kioto, Japón
China
HORIBA, Ltd. 51 series
- Fabricante: Horiba
Measuring principle: Non-Dispersive Infrared Absorption Method (NDIR) | Component: CO, CO 2 , CH 4 , etc. *1 | Span ±0.5% of full scale: Span : ±1.0% of full scale | Linearity: ±1.0% of full scale | Optional ran...
Kioto, Japón