GF1060 Laboratory Current Transformer Test System
Accuracy class: ±3% +0.025VA | Standard current measurement range: 1% ~120% In, 0.05% RD (In=1A or In=5A) | Tested current measurement range: 1% ~120% In, 0.05% RD (In=1A, In=5A) | Tested small signal input volta...
Pekín, ChinaT-213S Three Phase Transformer Dc Resistance Test Equipment
Power supply: Single phase AC 220V±10% or 110V±10% , 50/60HzAC | Cooling way: Intermittent air cooled | Single channel current output: 1A, 5A, 10A, 20A | Three channel current output: 1A+1A, 5A+5A, 10A+10A | Test...
Pekín, ChinaGf1060M Miniature Current Transformer Test Equipment
Accuracy class: Ratio error | Power supply: Single phase AC 220V±10% or 110V±10% , frequency 50/60Hz | Range: 0.2A, 1A, 5A | Adjustment range: (0-120)%RG | Adjust fineness: 0.01%RG | Accuracy: 0.05% RD | Stabilit...
Pekín, ChinaT-213 Transformer winding DC resistance tester
Power supply: Single phase AC 220V±10% or 110V±10% , 50/60Hz AC | Cooling way: Intermittent air cooled | Current output: 10mA, 100mA, 1A, 5A, 10A, 20A | Test voltage: DC 28V | Test range: 1mΩ-1Ω (20A) | Accuracy:...
Pekín, ChinaT-218 Automatic Portable Transformer Demagnetization Tester
Suministro de energía: AC monofásico 220V±10% o 110V±10%, 50/60Hz AC | Forma de refrigeración: Enfriado por aire intermitente | Salida de corriente: 200 mA, 1 A, 5 A (10 A, 20 A, 50 A opcional) | Lcd: Pantalla TF...
Pekín, ChinaGF106FY Current transformer & voltage transformer burden box
Accuracy class: 3 | Rated current: 5A, 1A | Power factor and rated capacity iec60044-1/iec61869-2: COSФ=0.8: 2.5/3.75/5/6.25/7.5/10/12.5/15/20/30/40/50/60VA COSФ=1.0: 2.5/3.75/5/6.25/7.5/10VA | Power factor and r...
Pekín, ChinaTEST-200 200A portable primary current injection test kit
Accuracy: <0.2% | Power supply(ac): 220V±10% 2000VA, 50Hz/60Hz or 110V±10% 2000VA, 50Hz/60Hz | Current output (ac): 200A·5V or 100A·10V | Capacity: 2KVA | The current output waveform distortion: ≤5% | Dual protec...
Pekín, ChinaTEST-903 electrical 3000A primary current injection test equipment
Precisión: <0,2% ±5 palabras | Fuente de alimentación (ca): 380V±10% 50A, 50Hz/60Hz | Salida de corriente (ca): 3000A·5V o 1500A·10V | Capacidad: 15KVA | La distorsión de la forma de onda de salida de corriente: ...
Pekín, ChinaTEST-901 large current 1000a primary current injection test set
Accuracy: <0.2% ±2words | Power supply (ac): 220V±10% 25A, 50Hz/60Hz or 110V±10% 50A, 50Hz/60Hz | Current output (ac): 1000A·5V or 500A·10V | Capacity: 5KVA | The current output waveform distortion: ≤5% | Dual pr...
Pekín, China- Pekín, China
GF1061CVT portable capacitor voltage transformer tester
Accuracy: ≤0.05S | Power supply: AC 100-265V, 50/60Hz or battery | Output current: 0-5Arms (20A peak-value) | Output power: 0-400VA (1500 VApeak) | Automatic frequency variation range: 0.1-60Hz | Secondary windin...
Pekín, ChinaGF1061PT portable voltage transformer tester
Accuracy: ≤0.05% | Power supply: AC 220V±10% or AC 120V±10% , 50/60Hz or battery | Output voltage: 0-100Vrms | Output current: 0-5Arms (20A peak-value) | Output power: 0-400VA (1500 VApeak) | Automatic frequency ...
Pekín, ChinaGF1061R instrument transformer turns ratio test set
Precisión: 0.05% | Suministro de energía: AC 220V±10% o AC 120V±10%, 50/60Hz | Rango de tensión: 0-100Vrms | Resolución: 0.1V | Gama actual: 0-500mA | Precisión actual: ±1mA, ±0.05% de la lectura ±1 dígito | Razó...
Pekín, ChinaPortable precision current transformer testing ct pt analyzer
Accuracy: ≤0.02% or 0.05% | Power supply: 85-265V AC, 50/60Hz or battery | Output voltage: 0-100Vrms | Output current: 0-5Arms (20A peak-value) | Output power: 0-400VA (1500 VApeak) | Automatic frequency variatio...
Pekín, ChinaGF106T portable ct pt analyzer
Accuracy: ≤0.2% | Power supply: AC 220V±10% or AC 110V±10% , 50/60Hz | Excitation voltage output: 0-2500Vrms | Excitation current output: 0-5Arms (20A peak-value) | Large current output: 0-1000A | Large current c...