HORIBA, Ltd. ENDA-7000 Series
- Fabricante: Horiba
This product is available in the following countries and territories: United States | Repeatability: ±0.5% full-scale ±0.1% full-scale (optional range) | Zero drift: ±1.0% full-scale per week ±2.0% ...
Kioto, JapónTCA-5000
Measurement principle: Thermal conductivity detection method | Measurement range: (Min.) 0 - 10 vol% (Max.) 0 - 100 vol% | Measurement range (optional): 0 - 5 vol% to less than 10 vol% 100 - 90 vol...
Kioto, JapónHORIBA, Ltd. APHA-380
- Fabricante: Horiba
Component: Methane, non-methane hydrocarbons, total hydrocarbons (CH 4 , NMHC, THC) | Measuring principle: Flame lonization Detector Method (FID) with Selective Combustion | Measurement range: 0-5/10/20/50/100 pp...
Kioto, JapónHORIBA, Ltd. APMA-380
- Fabricante: Horiba
Component: Carbon monoxide (CO) | Measuring principle: Cross-Modulation Non-Dispersive Infrared Absorption (NDIR) | Measurement range: 0-5/10/20/50/100/300 ppm (up to 6 ranges selectable, auto-range) | Lower dete...
Kioto, JapónHORIBA, Ltd. APOA-380
- Fabricante: Horiba
Component: Ozone (O 3 ) | Measuring principle: Cross-Modulation Non-Dispersive Ultraviolet Absorption (NDUV) | Measurement range: 0 - 0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 5.0 / 10 ppm *1 (up to 7 ranges selectable,...
Kioto, JapónHORIBA, Ltd. APNA-380
- Fabricante: Horiba
Component: Nitrogen oxides (NO, NO 2 , NOx) | Measuring principle: Cross-Modulation Chemiluminescence | Measurement range: 0-0.1/0.2/0.5/1.0/2.0/5.0/10/20 ppm (up to 8 ranges selectable, auto-range) | Lower detec...
Kioto, JapónHORIBA, Ltd. 51 series
- Fabricante: Horiba
Measuring principle: Non-Dispersive Infrared Absorption Method (NDIR) | Component: CO, CO 2 , CH 4 , etc. *1 | Span ±0.5% of full scale: Span : ±1.0% of full scale | Linearity: ±1.0% of full scale | Optional ran...
Kioto, JapónHORIBA, Ltd. GI-700
- Fabricante: Horiba
Indicated error (linearity): ± 1.0 % of full-scale value for each component and range (Standard range ratio) ± 2.0 % of full-scale value for each component and range (Optinonal range ratio) | Zero drift: ± 1.0%/w...
Kioto, JapónHORIBA, Ltd. ENDA-5000
- Fabricante: Horiba
Repeatability: Within 0.5% of full scale/week (with optional range, or during O 2 measurement, ±1.0% of full scale/week) | Linearity (indicator error): ±1.0% of full scale | Zero drift: ±1.0% of full scale/week (...
Kioto, JapónPS-300S
- Fabricante: Horiba
Measurement principle: NDIR: Non-Dispersive Infrared | Linearity: ±2% full scale | Zero drift: ±2% full scale per day | Span drift: ±2% full scale per day | Sample gas flow rate: Max. 0.5 L/min | Display: 5.7-inc...
Kioto, JapónHORIBA, Ltd. PG-300 series
- Fabricante: Horiba
Nox: 0-25/50/100/250/500/1000/2500 ppm | So2 ,co, ch4: Cross-Modulation Non-Dispersive Infrared Absorption Method | O2: 0-5/10/25 vol% (Zirconia Method, or Galvanic Method) 0-10/25 vol% (Paramagnetic Method (Dum...
Kioto, JapónPLGA-1000
Name: Process Laser Gas Analyzer | Measurement principle: NDIR: Non Dispersive Infrared | Light source: QCL: Quantum Cascade Laser | Laser class: Class 1(IEC 60825-1:2014) | Components*¹: Methane (CH 4 ), Ethane ...
Kioto, JapónStandard type: MEXA-ONE-FT Euro VI compliance type: MEXA-ONE-FT-E
- Fabricante: HORIBA, Ltd.
Conformed standards: CE, FCC, KC | Target components and ranges*1: Maximum 28 components Standard component set: for gasoline/diesel vehicle (18 components and “NO+NO 2 ”) Optional component set: for CNG-fueled v...
Kioto, JapónMEXA-ONE-QL-NX
- Fabricante: HORIBA, Ltd.
Measuring principle: Quantum Cascade Laser Infrared (QCL-IR) Spectroscopy | Measuring components: NO・NO 2 ・N 2 O・NH 3 | Measuring range: NO: (low) 0-100 ppm (high) 0-5000 ppm NO 2 :(low) 0- 50 ppm (h...
Kioto, Japón