Building Filters
VIS / NIR Fiber Coupled Light Source, Long Life
- Fabricante: B&W Tek
$750 USDWhite Bear Lake, MinnesotaVIS / NIR Fiber Coupled Light Source, High Power
- Fabricante: B&W Tek
$1,430 USDWhite Bear Lake, MinnesotaPLS-LAM Series DC Long Arc Mercury Lamp Light Source
- Fabricante: Mercury
Suministro de energía: AC220 V/6 A | Estabilidad de salida: �����0.85% | Método de refrigeración: Enfriamiento por aire forzado para la unidad principal, la bombilla puede enfriarse externamente con un ventilador...
Pekín, ChinaCHF-XM Series Xenon Lamp Light Source
- Fabricante: Perfectlight
Point light output diameter: 4~6 mm | Parallel light data diameter: 50 mm | Divergence angle: 0.85�� (Working Distance < 250 mm) | Spectral range: 300~1100 nm
Pekín, ChinaHORIBA Scientific Tunable Deuterium and Tungsten-Halogen Light Sources
- Fabricante: Horiba
Focal distance: 3.62 inches, 92 mm, from front of housing | Housing dimensions: 8.44 x 6 x 5.19 inches, 214 x 152 x 132 mm (L x W x H) | Weight: 12 pounds, 5.45 kg
Kioto, JapónUltraFast QPCR (FQ-8A)
Run time for 40-cycle pcr reaction: 30 minutes | Average heating-up rate: 50℃ – 90℃,≥3.0℃/s | Maximum heating-up rate: 50℃ – 90℃,≥6.0℃/s | Average cooling rate: 90℃ – 50 ℃,≥3.5℃/s | Maximum cooling rate: 90℃ – 50...
Vancouver, CanadáHORIBA Scientific Veloci Wine Analyzer
- Fabricante: Horiba
Detection limit: Parts per billion (sample and wavelength dependent) | Excitation/absorbance wavelength range: 200 to 800 nm | Fluorescence emission wavelength range: 250 to 800 nm | Wavelength accuracy: +/- 1 nm...
Kioto, JapónHORIBA Scientific Veloci BioPharma Analyzer
- Fabricante: Horiba
Detection limit: Parts per billion (sample and wavelength dependent) | Excitation/absorbance wavelength range: 200 to 800 nm | Fluorescence emission wavelength range: 250 to 800 nm | Wavelength accuracy: +/- 1 nm...
Kioto, JapónQM-800
Light source: High efficiency continuous Xenon arc lamp. 75W standard, 150W optional | Excitation wavelength selection: Patented DeltaRAM X™ random access monochromator | Excitation wavelength range: 290–650 nm u...
Kioto, JapónHORIBA Scientific FLIMera
- Fabricante: Horiba
Modality: Widefield Time-Domain TCSPC | Sensor: SPAD CMOS with In-Pixel TDC | Sensor wavelength range: 400 to 900 nm | Max total count rate: Up to 295 Mcps theoretical | Max pixel count rate: 12 kcps | Image arra...
Kioto, JapónHORIBA France SAS Smart SE
- Fabricante: Horiba
Spectra range: 450nm to 1000nm | Spectra resolution: Better than 3nm | Light source: Combined Halogen and Blue LED | Measurement time: <1sec to 10 sec | Beam size: 75µm * 150µm, 100µm * 250µm, 100µm * 500µm, 1...
Kioto, JapónAqualog®-Next: The Future of Water Analysis is Here
Webinar integrated characterization of organic matter for water treatment optimization: Google “Positive Current | SEARCH ON” on YouTube | Global warming causing canada's permafrost to release ancient bacteria: L...
Kioto, JapónUltraviolet Fluorescent Oil Pollution Remote Sensing Detector ATF2500
Spectral range: 300-700nm | Light source: Pulsed deep ultraviolet light source | Weight: 1.6 kg | Power supply: Standard 12 VDC(10-30V) | Measuring distance: 0~10 meters above water or ground | Detection object: ...
Xiamen, ChinaHORIBA Scientific Fluorolog-QM
- Fabricante: Horiba
Signal-to-noise ratio: (>35,000:1 FSD) | Data acquisition rate: 1,000,000 points/sec. to 1 point/1000 sec. | Inputs: 4 photon counting (TTL); 4 analog (+/- 10 volts); 1 analog reference channel (+/- 10 volts);...
Kioto, JapónHORIBA Scientific SpectraLED
- Fabricante: Horiba
Kioto, Japón