GF1061R instrument transformer turns ratio test set
Precisión: 0.05% | Suministro de energía: AC 220V±10% o AC 120V±10%, 50/60Hz | Rango de tensión: 0-100Vrms | Resolución: 0.1V | Gama actual: 0-500mA | Precisión actual: ±1mA, ±0,05% de la lectura ±1 dígito | Razó...
Pekín, ChinaGF106T portable ct pt analyzer
Accuracy: ≤0.2% | Power supply: AC 220V±10% or AC 110V±10% , 50/60Hz | Excitation voltage output: 0-2500Vrms | Excitation current output: 0-5Arms (20A peak-value) | Large current output: 0-1000A | Large current c...
Pekín, ChinaGF1061CVT portable capacitor voltage transformer tester
Accuracy: ≤0.05S | Power supply: AC 100-265V, 50/60Hz or battery | Output current: 0-5Arms (20A peak-value) | Output power: 0-400VA (1500 VApeak) | Automatic frequency variation range: 0.1-60Hz | Secondary windin...
Pekín, ChinaGF1061CT Portable ct analyzer with printer
Accuracy: ≤0.02% or 0.05% | Power supply: Single phase AC 85-265V, 50/60Hz or battery | Output current: 0-5Arms (20A peak-value) | Output power: 0-400VA (1500 VApeak) | Automatic frequency variation range: 0.1-60...
Pekín, ChinaGF1061PT portable voltage transformer tester
Accuracy: ≤0.05% | Power supply: AC 220V±10% or AC 120V±10% , 50/60Hz or battery | Output voltage: 0-100Vrms | Output current: 0-5Arms (20A peak-value) | Output power: 0-400VA (1500 VApeak) | Automatic frequency ...
Pekín, ChinaPortable precision current transformer testing ct pt analyzer
Accuracy: ≤0.02% or 0.05% | Power supply: 85-265V AC, 50/60Hz or battery | Output voltage: 0-100Vrms | Output current: 0-5Arms (20A peak-value) | Output power: 0-400VA (1500 VApeak) | Automatic frequency variatio...
Pekín, China- Shanghái, China
Epoxy Resin Vacuum Casting Machine
- Fabricante: WUXI HAOSHUO TECHNOLOGY
Tamaño del tanque de vacío: Φ1800×2000mm a Φ3200×3500mm | Tanque de mezclado: 3 tanques según diseño | Entada de fundición: 6 a 12 según diseño | Temperatura de calentamiento: 70 a 85°C ajustable | Vacío límite: ...
Jiangsu, ChinaGF1060 Laboratory Current Transformer Test System
Accuracy class: ±3% +0.025VA | Standard current measurement range: 1% ~120% In, 0.05% RD (In=1A or In=5A) | Tested current measurement range: 1% ~120% In, 0.05% RD (In=1A, In=5A) | Tested small signal input volta...
Pekín, ChinaP110 1000A cable fault analysis clamp current transformer
Ratio: 10001 or 20001 (customized) | Accuracy class: 0.1% , 0.2% , 0.5% , 1% | Primary current: 0-1000A AC | Secondary voltage: 0-10V AC (customized) | Max. cont. input current: 1200A | Over voltage category: CAT...
Pekín, China