Building Filters
GF1061PT portable voltage transformer tester
Accuracy: ≤0.05% | Power supply: AC 220V±10% or AC 120V±10% , 50/60Hz or battery | Output voltage: 0-100Vrms | Output current: 0-5Arms (20A peak-value) | Output power: 0-400VA (1500 VApeak) | Automatic frequency ...
Pekín, ChinaT&R TEST KV50-20D MK2 Test System
- Fabricante: T&R
Control unit weight: 17 kg | Control unit dimensions: 380 x 314 x 221 mm | Transformer weight: 75 kg | Transformer dimensions: 490 x 520 x 795 mm | Supplied accessories: User manual; Calibration certificate; Spar...
Guildford, Reino UnidoFor Parts BIOMERIEUX Vidas
- Fabricante: Biomerieux
- Modelo: VIDAS
Shipping from: Italy | Analizator type: Automatic | Type of analyzer: closed
$1,173 USDPortici, ItaliaFor Parts BIOMERIEUX Vidas
- Fabricante: Biomerieux
- Modelo: VIDAS
Shipping from: Italy | Analizator type: Automatic | Type of analyzer: closed
$1,173 USDPortici, ItaliaPOWDER IMPEDANCE MEASUREMENT SYSTEM
Frequency at which measurements can be made: DC to 5 MHz (Three types of measuring instruments used) | Load application method: Manual operation (constant control of load is not possible) | Load range (compressin...
Nagano, Japón3656 Series Vector Network Analyzer
Parameters: 3656D | Frequency range: 300kHz-20GHz | Frequency resolution: 1Hz | Frequency accuracy: ±1×10-6(23℃±3℃) | System dynamic range: (10Hz) (3kHz)100kHz-1MHz 90dB 60dB1MHz-10MHz 110 dB 80 dB10MHz-3GHz 125d...
Qingdao, ChinaE&I Engineering
- Fabricante: LEHUI
Ningbo, ChinaInfrared CH4 meter GJH4(A)
Gama de pruebas: 0.00%CH4~4.0%CH4 | Temperatura ambiente: 0°C~40°C | Humedad relativa: ≤98%HR | Presión atmosférica: 80 kPa~116 kPa | Velocidad del viento: 0 m/s~8 m/s | Frecuencia: 200 Hz~1000 Hz | Actual: 250 g...
Pekín, ChinaGPD10 Mining Differential Pressure Meter
Testing range: 0〜10KPa | Environment temperature: 0℃~40℃ | Relative humidity: ≤98%RH | Atmosphere pressure: 80kPa~116kPa | Frequency: 200Hz~1000Hz | Response time: 30s | Dimension: 270mm× 155 mm× 55mm | Weight: ≤...
Pekín, ChinaGWD100 Mining Temperature Meter
Testing range: 0℃〜100℃ | Environment temperature: 0℃~40℃ | Relative humidity: ≤98%RH | Atmosphere pressure: 86kPa~116kPa | Frequency: 200Hz~1000Hz | Working current: ≤8mA | Working voltage: DC9V~24V | Dimension: ...
Pekín, ChinaHydrogen Sulfide Sensor/H2S Meter
Gama de pruebas: 0-100 ppm H2S | Temperatura ambiente: 0℃~40℃ | Humedad relativa: ≤98%HR | Presión atmosférica: 80 kPa~116 kPa | Velocidad del viento: 0 m/s~8 m/s | Punto de alarma: 0~20×10-6H2S ajustable | Tiemp...
Pekín, ChinaKINGSINE KS833 Three-phase Power Source Calibrator
- Fabricante: Kingsine
Available ranges: 100mA, 1A, 5A, 10A, 25A; auto-shift | Adjustment range: 0~120%Rg | Adjustment fineness: Range x 0.01% | Resolution: Range x 0.01% | Accuracy: 0.01%Rg | Stability: 0.01% / 1min | Frequency range:...
Shenzhen, ChinaHORIBA Advanced Techno Co., Ltd. HE-200H
- Fabricante: Horiba
Product name: Conductivity meter | Sensors in combination: 4-electrode method conductivity sensor (FES Series) of cell constant 0.1/cm, or 1.0/cm | Display range: 0.0 to 220.0 | Temperature: 0.01℃ | Nacl: 0.0% to...
Kioto, JapónHydraulic Embossing Press Machine
- Fabricante: MYT(Shanghai) Machinery Equipment Co.,Ltd
Technical parameter: unit | Nominal force: KN | Liquid work force: Mpa | Return force: KN | Slide stroke: mm | Max.opening: mm | Effective workingtable: mm×mm | Air-way fast drop speed: mm/s | Slow down speed: mm...
Shanghái, ChinaYamato CIW1100
- Fabricante: Yamato
Circulation method: External closed system circulation | Cooling method: Water-cooled type | Temperature control range: 0 - 80℃ (Operation of entire freezer) | Operating temperature range: 5 - 35℃ | Temp. adjustm...
Tokio, Japón