Building Filters
Fluke 8508A
- Fabricante: Fluke
- Modelo: 8508A
Lake Mary, FloridaFluke 45
- Fabricante: Fluke
Lake Mary, FloridaWavetek 1271
- Fabricante: Wavetek
- Modelo: 1271
Lake Mary, FloridaDIGITAL MULTIMETER DT4256
Dc voltage range: 600.0 mV to 1000 V, 5 ranges Basic accuracy: ±0.3 % rdg. ±3 dgt. | Ac voltage range: 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz Basic accuracy 40 - 500 Hz : ±0.9 % rd...
Nagano, JapónAC/DC CURRENT SENSOR CT6872
Rated current: 50 A AC/DC | Max. allowable input: Within the derating range, up to ±150 A peak (design value) allowed at 40°C or less for 20 ms or less | Frequency bandwidth: Amplitude: DC to 10 MHz Phase: DC to ...
Nagano, JapónAC/DC CURRENT SENSOR CT6873
Rated current: 200 A AC/DC | Max. allowable input: Within the derating range, up to ±420 A peak (design value) allowed at 40°C or less for 20 ms or less | Frequency bandwidth: Amplitude: DC to 10 MHz Phase: DC to...
Nagano, JapónDIGITAL MULTIMETER DT4252
Dc voltage range: 600.0 mV to 1000 V, 5 ranges Basic accuracy: ±0.3 % rdg. ±5 dgt. | Ac voltage range: 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz - 1 kHz Basic accuracy 40 - 500 Hz : ±0.9 % rdg...
Nagano, JapónDIGITAL MULTIMETER DT4282
Dc voltage range: 60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt. | Ac voltage(*1) range: 60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHz Basic accuracy 45 - 65 ...
Nagano, JapónCLAMP ON PROBE 9010-50
Rated current: 10 A to 500 A AC, 6 ranges | Accuracy: ±2 % rdg. ±1 % f.s. (45 to 66 Hz) | Frequency characteristics: Add to amplitude accuracy for frequencies from 40 to 1 kHz: ± 6 % rdg. (at 10 A and 20 A range)...
Nagano, JapónCLAMP ON PROBE 9132-50
Rated current: 20 A to 1000 A AC, 6 ranges | Accuracy: ±3 % rdg. ±0.2 % f.s. (45 to 66 Hz) | Frequency characteristics: Add to amplitude accuracy for frequencies from 40 to 1 kHz: ± 1 % rdg. | Output rate: 0.2 V ...
Nagano, JapónCLAMP ON PROBE 9018-50
Rated current: 10 A to 500 A AC, 6 ranges | Accuracy: ±1.5% rdg. ±0.1% f.s. (45 to 66 Hz) | Frequency characteristics: Add to amplitude accuracy : ± 1% rdg. Add to phase accuracy : ± 2.5° for frequencies from 40 ...
Nagano, JapónDIGITAL MULTIMETER DT4223
Dc voltage range: 600.0 mV to 600.0 V, 4 ranges, Basic accuracy: ±0.5 % rdg. ±5 dgt. | Ac voltage range: 6.000 V to 600.0 V, 3 ranges, Frequency characteristics: 40 Hz - 1 kHz Basic accuracy 40 - 500 Hz : ±1.0 % ...
Nagano, JapónDIGITAL MULTIMETER DT4253
Dc voltage range: 600.0 mV to 1000 V 5 ranges, Basic accuracy: ±0.3 % rdg. ±5 dgt. | Ac voltage range: 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz Basic accuracy 40 - 500 Hz : ±0.9 % rd...
Nagano, JapónDIGITAL MULTIMETER DT4224
Dc voltage range: 600.0 mV to 600.0 V, 4 ranges, Basic accuracy: ±0.5 % rdg. ±5 dgt. | Ac voltage range: 6.000 V to 600.0 V, 3 ranges, Frequency characteristics: 40 Hz - 1 kHz Basic accuracy 40 - 500 Hz : ±1.0 % ...
Nagano, JapónDIGITAL MULTIMETER DT4281
Dc voltage range: 60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt. | Ac voltage(*1) range: 60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHz Basic accuracy 45 - 65 ...
Nagano, Japón