Building Filters
Wireless Seismic Sensor Portable Seismic Recorder Seismic Data Logger
Redundancia del sistema: Sistemas de doble alimentación | Comunicación: Múltiples opciones de canal | Movilidad: Diseño ligero y portátil | Visibilidad: Carcasa de alta visibilidad
Chongqing, ChinaGF112L Leakage Current Data Logger And Leakage Current Tester
Accuracy class: 0.05% | Power supply: AAA type, 3PCS, Li rechargeable battery, 2700mAh, 3.6Vit can work 48 hours continuously | Warming-up time: <2min | U range: 0-720V | Accuracy: 0.0002 | Harmonics: 2nd-31st | ...
Pekín, ChinaNON-CONTACT CAN SENSOR SP7001, SP7002
Detection method: Capacitive-coupled signal detection No bare-wire connections | Detectable cables: AVS/AVSS-compliant cables, External diameter: 1.2 mm (0.05 in) to 2.0 mm (0.08 in) | Number of channels: 1 CH (S...
Nagano, JapónGF112T Transformer Core Leakage Current Tester
Accuracy class: 0.05%, 0.1%, 0.2% | Power supply: AAA type, Li rechargeable battery, 2700mAh, 3.6Vit can work 48 hours continuously | Warming-up time: <2min | U range: 0-600.00V | Accuracy: 0.0002 | Harmonics: 2n...
Pekín, ChinaWIRELESS VOLTAGE/TEMP LOGGER LR8515
Functionality: [Used as standalone product (Data collected manually) ] Windows PC or Windows tablet (CD-R with software included) Android smartphone or Android tablet terminal (Software can be downloaded free of ...
Nagano, JapónHEAT FLOW LOGGER LR8432
Specialized functions for heat flow measurement: - Easy scaling settings: directly enter the sensitivity of the heat flow sensor - Calculations: waveform processing function for the analysis of temperature and he...
Nagano, JapónAC/DC AUTO-ZERO CURRENT SENSOR CT7731
Rated measurement current: 100 A AC/DC | Max. measurement current: 100 A (requires derating at frequency) | Max. allowable peak input: 150 A peak | Bandwidth: DC to 5 kHz (-3dB) (When used in combination with CM...
Nagano, JapónAC/DC AUTO-ZERO CURRENT SENSOR CT7742
Rated measurement current: 2000 A AC/DC | Max. measurement current: 2000 A (requires derating at frequency) | Max. allowable peak input: 2840 A peak | Bandwidth: DC to 5 kHz (-3dB) (When used in combination with...
Nagano, JapónAC/DC AUTO-ZERO CURRENT SENSOR CT7736
Rated measurement current: 600 A AC/DC | Max. measurement current: 600 A (requires derating at frequency) | Max. allowable peak input: 900 A peak | Bandwidth: DC to 5 kHz (-3dB) (When used in combination with CM...
Nagano, JapónAC/DC CURRENT SENSOR CT7636
Rated measurement current: 600 A AC/DC | Max. measurement current: 600 A (requires derating at frequency) | Max. allowable peak input: 900 A peak | Bandwidth: DC to 10 kHz (-3dB) (When used in combination with C...
Nagano, JapónAC/DC CURRENT SENSOR CT7642
Rated measurement current: 2000 A AC/DC | Max. measurement current: 2000 A (requires derating at frequency)) | Max. allowable peak input: 2840 A peak | Bandwidth: DC to 10 kHz (-3dB) (When used in combination wi...
Nagano, JapónAC/DC CURRENT SENSOR CT7631
Rated measurement current: 100 A AC/DC | Max. measurement current: 100 A (requires derating at frequency)) | Max. allowable peak input: 150 A peak | Bandwidth: DC to 10 kHz (-3dB) (When used in combination with ...
Nagano, JapónDISPLAY UNIT CM7290
Sensor: CT7642, 7742 | Measurement parameters: DC, AC, DC+AC, Hz | Crest factor: 3 at 5000 count or 2.5 at 6000 count for AC and DC+AC | Output method: WAVE, RMS, PEAK, FREQ | Input connectors: HIOKI PL 14 | Outp...
Nagano, JapónProbadora para Envases GT-A
Modelos: GT-A | Envases detectados: envases tres piezas, envases dos piezas, cubetas, bidones, botes, tubos, aerosol, envases compuestos, monobloc | Llenado de envase: vacío | Tipo de máquina: probador de fugas l...
Shantou, ChinaMedical Infusion Heater Machie ME2000
Me2000: Pantalla LED destacada; | Rango de temperaturas: 28℃- 41℃( ±1℃) | Humedad: 35 – 95 %HR (No condensing) | Caudal: 1-15ml/min
Shanghái, China